Connecting Power to Cisco RFGW-10 UEQAM
Figure 3-18
Note
To avoid hazardous conditions, all components in the area where DC input power is accessible must be
properly insulated. Therefore, before installing the DC cable lugs, be sure to insulate the lugs according
to the manufacturer's instructions.
Caution
Before installing the DC cable lugs, ensure proper insulation of the entire 90 degree portion of the lugs
where the wire is crimped to avoid hazardous conditions and where the DC input power is accessible
through the terminal cover of the DC PEM with shrink tubing.
Note
Detailed instructions for removing and replacing the Cisco RFGW-10 UEQAM DC PEM are in
"Installation and Removal of the DC PEM" section on page
To connect the DC PEM, follow these steps:
Note
Make sure that the facility input power is removed safely from the power cables before and during wiring
of the input power cables.
Step 1
Make certain that the chassis grounding is connected before you begin installing the DC PEM.
Cisco RF Gateway 10 Hardware Installation Guide
3-24