The Cisco RFGW-10 UEQAM is installed in a standard 19-inch equipment or telco rack. A rack-mount
kit ships from the Cisco factory with each router. The rack-mount kit includes the hardware needed to
mount the router in a standard 19-inch equipment rack or telco-type rack. Mounting in 23-inch
equipment rack is possible with optional third-party mounting hardware.
The components in the front include the Supervisor Cards, RF line cards, and the front panel LCD. The
components on the rear include the Fan Assembly, RF Switch cards (coaxial terminations), TCC (DTI
Clock) cards, and the power supply modules.
All components (excluding the LCD) are hot-swappable and field replaceable. A fully configured system
will operate with a single DC PEM installed; the second PEM is required for power supply redundancy
and power load sharing.
Note
Proper configuration of the DC power input requires that both Input 1 and Input 2 are connected to the
external power source and the GND connections are connected to the Earth GND. Input 1 and Input 2
on the DC PEMs are not redundant power inputs. If only one of the inputs is connected to the external
power, the Cisco RFGW-10 UEQAM will not power-on correctly.

Cisco RFGW-10 Slot Numbering

The figures below show the slot numbering in a Cisco RFGW-10 chassis.
Figure 1-2
Cisco RFGW-10 Slot Numbering