Appendix
A.3 Tags of the technology object external encoder
A.3.12

ErrorDetail tags (external encoder)

The tag structure <TO>.ErrorDetail.<tag name> contains the alarm number and the effective
local alarm reaction to the technology alarm that is currently pending at the technology
object.
A list of the technology alarms and alarm reactions can be found in the appendix,
Technology Alarms (Page 368).
Tags
Legend (Page 358)
Tag
ErrorDetail.
Number
Reaction
366
Data type
Values
STRUCT
UDINT
-
DINT
0 to 5
W
Description
RON
Alarm number
RON
Effective alarm reaction
0: No reaction
1: Stop with current dynamic values
2 Stop with maximum dynamic values
3: Stop with emergency stop ramp
4: Remove enable
5: Follow-up setpoints
For the external encoder technology object, only
alarm reactions 0 and 4 are possible.