Modulo Tags (External Encoder); Homing Tags (External Encoder) - Siemens SIMATIC S7-1500 Function Manual

Update 3
Hide thumbs Also See for SIMATIC S7-1500:
Table of Contents

Advertisement

Appendix
A.3 Tags of the technology object external encoder
A.3.7

Modulo tags (external encoder)

The tag structure <TO>.Modulo.<tag name> contains the modulo configuration.
Tags
Legend (Page 358)
Tag
Modulo.
Enable
Length
StartValue
A.3.8

Homing tags (external encoder)

The tag structure <TO>.Homing.<tag name> contains the configuration for homing the TO.
Tags
Legend (Page 358)
Tag
Homing.
HomePosition
362
Data type
Values
STRUCT
BOOL
-
LREAL
0.001 to 1.0E12
LREAL
-1.0E12 to
1.0E12
Data type
Values
STRUCT
LREAL
-1.0E12 to
1.0E12
W
Description
RES
FALSE: Modulo conversion disabled
TRUE: Modulo conversion enabled
When modulo conversion is enabled, a check is
made for modulo length > 0.0
RES
Modulo length
RES
Modulo start value
W
Description
DIR
Home position