A.4.6

Technology alarms 501-550

Technology alarm 501
Alarm reaction: No reaction
Restart: Not required
Alarm text
Programmed velocity limited.
Technology alarm 502
Alarm reaction: No reaction
Restart: Not required
Alarm text
Programmed acceleration/deceleration limited.
Acceleration
Deceleration
Technology alarm 503
Alarm reaction: No reaction
Restart: Not required
Alarm text
Programmed jerk limited.
S7-1500 Motion Control V13 Update 3
Function Manual, 07/2014, A5E03879256-AC
Solution
Check the value for the speed of the Motion Control
instruction.
Check the configuration of the dynamic limits.
Solution
Check the value for the acceleration of the Motion Con-
trol instruction.
Check the configuration of the dynamic limits.
Check the value for the deceleration of the Motion Con-
trol instruction. Check the configuration of the dynamic
limits.
Solution
Check the value for the jerk of the Motion Control in-
struction.
Check the configuration of the dynamic limits.