Loadgear Tags (Speed Axis) - Siemens SIMATIC S7-1500 Function Manual

Update 3
Hide thumbs Also See for SIMATIC S7-1500:
Table of Contents

Advertisement

Tag
EnableDriveOutput BOOL
EnableDrive
OutputAddress
EnableDrive
OutputBitNumber
DriveReadyInput
DriveReady
InputAddress
DriveReady
InputBitNumber
DriveParameter.
ReferenceSpeed
MaxSpeed
A.1.5

LoadGear tags (speed axis)

The tag structure <TO>.LoadGear.<tag name> contains the configuration for the load gear.
Tags
Legend (Page 321)
Tag
LoadGear.
Numerator
Denominator
S7-1500 Motion Control V13 Update 3
Function Manual, 07/2014, A5E03879256-AC
Data type
Values
-
UDINT
0 to 65535
UDINT
0 to 7
BOOL
-
UDINT
0 to 65535
UDINT
0 to 7
LREAL
0.0 to 1.0E12
LREAL
0.0 to 1.0E12
Data type
Value range
STRUCT
UDINT
1 to
4294967295
UDINT
1 to
4294967295
A.1 Tags of the technology object SpeedAxis
W
Description
RON
"Enable output" for analog drives
FALSE: disabled
TRUE: enabled
RON
Byte number for the "enable output"
RON
Bit number for the "enabling output"
RON
"Ready input" for analog drives
The analog drive signals its readiness to receive
setpoint speeds.
FALSE: disabled
TRUE: enabled
RON
Byte number for the "ready input"
RON
Bit number for the "ready input"
RES
Reference value (100%) for the setpoint speed of the
drive (N-set)
The setpoint speed is transmitted in the PROFIdrive
frame as a standardized value from -200% to 200%
of the "ReferenceSpeed".
For setpoint specification via an analog output, the
analog output can be operated in the range from -
117% to 117%, insofar as the drive permits this.
RES
Maximum value for the setpoint speed of the drive
(N-set)
(PROFIdrive: MaxSpeed ≤ 2 × ReferenceSpeed
Analog setpoint: MaxSpeed ≤ 1.17 × Refer-
enceSpeed)
W
Description
RES
Load gear counter
RES
Load gear denominator
Appendix
323

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic s7-1500 motion control v13

Table of Contents