4.5.26

Statistics

Counting and evaluation of received frames
An IE switch has internal statistics counters with which it counts the number of received
frames for each port according to the following criteria:
● Frame length
● Frame type
● Bad frames
This information provides you with an overview of the data traffic and any problems on the
network.
Figure 4-118 Statistics Throughput
Octets In
Shows the number of received bytes.
Octets Out
Shows the number of sent bytes.
Frames In
Shows the number of received frames.
Frames Out
Shows the number of sent frames.
Utilization
Displays the current port utilization as a percentage (%). If the bus utilization is less than 1%,
nothing is displayed. Depending on the frame length (system dependent), the display can
deviate by up to 20% since the proportion of pauses between frames increases the shorter
the frame.
SCALANCE X-300 / X-400
Configuration Manual, 10/2014, C79000-G8976-C187-22
Configuration using Web Based Management and Command Line Interface
4.5 The Switch menu
267