iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).ad(4196).adProductMibs(1).simaticN
et(1).iScalanceX(5).iScalanceX300X400(4)
Table B- 5
Variables
snX300X400FaultState
snX300X400ReportFaultIndex
snX300X400ReportFaultState
snX300X400RmMode
snX300X400RmState
snX300X400RmStateChanges
snX300X400StandbyMode
SCALANCE X-300 / X-400
Configuration Manual, 10/2014, C79000-G8976-C187-22
Private MIB variables of an IE switch
Access rights
Read only
Read only
Read only
Read only
Read only
Read only
Read only
B.1 MIB variables of a SCALANCE X300/X400
Description
Displays the status of the signaling contact. Pos-
sible values:
1
•
No error
2
•
Error.
Data type: Integer
Errors are assigned an ascending index accord-
ing to the order in which they occur. This 4-byte
variable specifies the index.
Contains the error message belonging to an in-
dex.
The redundancy manager mode:
The IE switch is redundancy manager.
•
The IE switch is not redundancy manager.
•
Indicates whether the redundancy manager is
active or passive.
Possible values:
The redundancy manager is passive. The IE
•
switch is operating as redundancy manager
and has opened the ring; in other words, the
line of IE switches connected to it is operating
problem-free. The "Passive" status is also
shown when the redundancy manager mode
is disabled.
The redundancy manager is active. The IE
•
switch is operating as redundancy manager
and has closed the ring; in other words, the
line of IE switches connected to it is interrupt-
ed (fault). The redundancy manager switches
through the connection between the ring ports
and thus restores a functioning bus configura-
tion.
Data type: Integer
Indicates how often the redundancy manager was
switched to "active".
Data type: Counter
The standby function mode:
The standby function is enabled.
•
The standby function is disabled.
•
Appendix B
373