Siemens SCALANCE X-300 Configuration Manual page 379

Industrial ethernet switches
Hide thumbs Also See for SCALANCE X-300:
Table of Contents

Advertisement

Message when an error occurs
Main power usage threshold exceeded.
Unexpected port assembly. Change device name
to %s.
Unknown SFP module on <port number> (ven-
dor: \"%$str\").
SFP module on <port number> is not supported
and remains deactivated.
Signaling contact controlled by user configura-
tion.
Local loop detected on <port number>. Port disa-
bled.
Local loop detected on <port number>. Port disa-
bled for <number of> seconds.
Remote loop detected on <port number>. Port
disabled.
Remote loop detected on <port number>. Port
disabled for <number of> seconds.
Local loop detected on <port number>.
Remote loop detected on <port number>.
Standby <partner | observer> conflicts
with <active | passive> state.
Standby <partner | observer> conflicts with ob-
server <on | off> configuration.
Standby <partner | observer> conflicts
with <master | slave> role.
Standby slave: At least one port has no link.
FMP-Port <port number>: Maintenance required,
Rx-Power: <received power> [dBm], Power
Loss: <power loss> [dB]
FMP-Port <port number>: Maintenance demand-
ed, Rx-Power: <received power> [dBm], Power
Loss: <power loss> [dB]
POF-Port <port number>: Maintenance required,
Rx-Power: <received power> [dBm], Power Mar-
gin: <power margin> [dB]
POF-Port <port number>: Maintenance demand-
ed, Rx-Power: <received power> [dBm], Power
Margin: <power margin> [dB]
Message to inform about an event that occurred
The following messages provide you with information about events that are not directly
related to an error status (error LED):
● User entry: <user entry>
● Unknown command <command> for <protocol name> protocol received.
SCALANCE X-300 / X-400
Configuration Manual, 10/2014, C79000-G8976-C187-22
D.1 Error messages of the SCALANCE X300 / X400
Messages after eliminating the problem
Main power usage below threshold again.
Port assembly known.
Unknown SFP module on <port number> re-
moved.
Not supported SFP module on <port number>
removed.
Signaling contact controlled by error state.
<Port number> is enabled again after being disa-
bled by loop detection.
<Port number> is enabled again after being disa-
bled by loop detection.
<Port number> is enabled again after being disa-
bled by loop detection.
<Port number> is enabled again after being disa-
bled by loop detection.
<port number> is enabled again for loop detec-
tion.
<port number> is enabled again for loop detec-
tion.
Standby <partner | observer>'s state conflict
resolved.
Standby <partner | observer>'s observer configu-
ration conflict resolved.
Standby <partner | observer>'s role conflict re-
solved.
Standby slave: All ports linked up.
FMP-Port <port number>: OK
FMP-Port <port number>: OK
POF-Port <port number>: OK
POF-Port <port number>: OK
Appendix D
379

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scalance x-400

Table of Contents