Figure 4-28
IP Address
Here, you enter the addresses of the stations to which an IE switch will send traps.
Enable Trap
Click on the check box next to the IP addresses to enable the sending of traps to the
corresponding stations.
Syntax of the Command Line Interface
Table 4- 22
Info
ip <entry> <ip>
state <entry><E|D>
SCALANCE X-300 / X-400
Configuration Manual, 10/2014, C79000-G8976-C187-22
Configuration using Web Based Management and Command Line Interface
SNMPv1 Trap Configuration
SNMPv1 Trap Configuration - CLI\AGENT\SNMP\TRAPCONF>
Command
Shows the current trap configuration.
Specifies the IP address of the trap recipient
entry (entry between 1 and 10).
Enables/disables the sending of traps to the
recipient entry (entry between 1 and 10)
Description
4.4 The Agent menu
Comment
-
Administrator only.
Default value: 0.0.0.0
Administrator only.
Default value: D