The Poe Menu Item - Siemens SCALANCE X-300 Configuration Manual

Industrial ethernet switches
Hide thumbs Also See for SCALANCE X-300:
Table of Contents

Advertisement

4.6

The PoE menu item

Settings for Power over Ethernet
SCALANCE devices of the "PoE" version, can supply other PoE-compliant devices with
power via an Ethernet cable. For each individual PoE port, you can specify whether or not
the power will be supplied via Ethernet. You can also set a priority for each connected
powered device (PD). Devices for which a high priority was set, take preference over other
devices for the power supply.
The overview page shows information on the power supplied by the SCALANCE device with
PoE and detailed information on each individual PoE port.
Figure 4-125 Information on the SCALANCE PoE configuration
Maximum Power [W] (read-only)
Maximum power that the SCALANCE provides to supply PoE devices.
Allocated Power [W] (read-only)
Sum of the power reserved by the PoE devices.
Power in Use [W] (read-only)
Sum of the power being used by the end devices.
Usage Threshold [%]
As soon as the power being used by the connected devices exceeds this percentage of the
maximum power, an event is triggered.
SCALANCE X-300 / X-400
Configuration Manual, 10/2014, C79000-G8976-C187-22
Configuration using Web Based Management and Command Line Interface
4.6 The PoE menu item
277