Hydraulic Specifications - Genie S-100 Service And Repair Manual

Hide thumbs Also See for S-100:
Table of Contents

Advertisement

Section 2 • Specifications
SPECIFICATIONS

Hydraulic Specifications

Hydraulic Fluid Specifications
Genie specifications require hydraulic oils which are
designed to give maximum protection to hydraulic
systems, have the ability to perform over a wide
temperature range, and the viscosity index should
exceed 140. They should provide excellent antiwear,
oxidation prevention, corrosion inhibition, seal
conditioning, and foam and aeration suppression
properties.
Cleanliness level, minimum
Water content, maximum
Recommended Hydraulic Fluid
Hydraulic oil type
Viscosity grade
Viscosity index
Optional Hydraulic fluids
Mineral based
Biodegradable
Fire resistant
Note: Genie specifications require additional
equipment and special installation instructions for the
approved optional fluids. Consult the Genie Product
Support before use.
Optional fluids may not have the
same hydraulic lifespan and may
result in component damage.
Note: Extended machine operation can cause the
hydraulic fluid temperature to increase beyond it's
maximum allowable range. if the hydraulic fluid
temperature consistently exceeds 200
optional oil cooler may be required.
2 - 6
ISO 15/13
250 ppm
Chevron Rando HD Premium
Shell Tellus S2 V 32
Shell Tellus S2 V 46
Chevron 5606A
Petro Canada Environ MV 46
UCON Hydrolube HP-5046
°F / 90°C an
S-100 • S-105 • S-120 • S-125
Note: Do not operate the machine when the ambient
air temperature is consistently above 120
Hydraulic Fluid Temperature
32
200
Range
1
-40
-22
-4
-40
-30
-20
1 Chevron hydraulic oil 5606A
2 Petro-Canada Environ MV 46
3 UCON Hydrolube HP-5046D
4 Chevron Rando HD premium oil MV
Do not top off with incompatible
hydraulic fluids. Hydraulic
fluids may be incompatible
due to the differences in base
additive chemistry. When
incompatible fluids are mixed,
insoluble materials may form and
deposit in the hydraulic system,
plugging hydraulic lines, filters,
control valves and may result in
component damage.
2
3
4
14
32
50
68
86
104
-10
-0
10
20
30
40
Ambient air temperature
Part No. 1268494
March 2017
°F / 49°C.
122
F
50
C

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S-120S-105S-125

Table of Contents