[129] E&M Signal Assignment
Description
Assigns the E&M signal. There are three signals available:
Continuous: Continuous E&M (Wink/Immediate)
Pulsed Ans: Pulsed E&M with Answer Signal (Wink only)
Pulsed No Ans: Pulsed E&M without Answer Signal (Wink only)
Selection
Continuous / Pulsed Ans / Pulsed No Ans
Default
Continuous
Programming
1.
Enter 129.
Display: 129 E&M SIGNAL
2.
Press NEXT.
Display example:Continuous
3.
Keep pressing SELECT until the desired selection is displayed.
4.
Press STORE.
5.
Press END.
Conditions
If you select "Pulsed Ans" or "Pulsed No Ans", you must select "Wink" as the start type.