[813] Floating Number Assignment

Description
Assigns the floating numbers for External Pagers, DISA (Direct Inward System Access)
messages, modem and extension groups. These numbers can be used in the same way extension
numbers are used for station access.
Selection
• Floating station:
Pager1 through 4 / DISA1 / DISA2 / MODEM / E-Grp 1 through 8
(Pager2 through 4 are available for the KX-TD1232 only.)
• Floating number: 2 through 4 digits
Default
Pager 1=196; Pager 2=197; Pager 3=296; Pager 4=297; DISA 1=198; DISA 2=298;
MODEM=299; E-Grp 1=191; E-Grp 2=192; E-Grp 3=193; E-Grp 4=194; E-Grp 5=291; E-
Grp 6=292; E-Grp 7=293; E-Grp 8=294
Programming
1.
Enter 813.
Display: 813 FLOATING #
2.
Press NEXT to programme Pager 1.
Display example: Pager1 :EXT196
To programme another floating station, keep pressing NEXT or PREV until the desired
floating station is displayed.
3.
Enter a floating number.
To change the current entry, press CLEAR and enter the new floating number.
4.
Press STORE.
5.
To programme another floating station, keep pressing NEXT or PREV until the desired
floating station is displayed.
6.
Repeat steps 3 through 5.
7.
Press END.
Conditions
• A floating number is composed of two through four numerical digits, 0 through 9.
• The first one or two digits of the floating numbers are subject to programme
[100] Flexible Numbering, (01) through (16) 1st through 16th hundred extension blocks.
• Floating numbers and extension numbers should be different. Double entry and
incompatible entry for these numbers are invalid. Valid entry example: 10 and 11, 10 and