Section 700 - Operation
Related Programming
l
l
FF4 (Ring): DID, Delayed, Night , Delayed Night, Night 2, and Delayed
l
Night 2 Ring Assignments
Hardware Requirements
Either the T-l Card or DID trunk card is required. Each DID trunk card
l
provides 8 ports.
The DID trunk card requires an external 48V power supply. See
l
Installation (Section
Considerations
The DID Trunk card supports 4-digit, dial-pulse DID.
l
. The Tl card supports 4-digit, dial-pulse or DTMF DID.
DID numbers must be between 0000 and 9999.
l
Beginning with CPC-B Version 3.1, a maximum of 500 DID/extension
l
settings is allowed.

DID Night Ringing Assignment

(CPC-B Version 5.0 or higher)
Description
For a description of this feature, see "DlWDNIS Flexible Ring Assignments"
on page 2- 18.
DBS-70-700
Multiple DID (CPC-B Version 3.1 or higher)
(Extension): Inbound DID Dial Number (CPC-B Version 2.0 to 2.16)
300) for instructions.
DBS Manual - Issued 8/l/95
Chapter 2. System teatures
Page 2-17