[109] Expansion Unit Type
Description
Assigns the type of expansion units to be used in the system.
This allows the system to identify the unit in each expansion unit location.
Selection
KX-TD816
• Areas 1; 2 = C (4 CO) / S2 (2 S0) / S6 (6 S0) / BD (4 DID-Pulse/DTMF) / MD (4 DID-
MFC) / EM (4 E&M) / E (EXT) / A (16 SLT)
KX-TD1232
• Master / Slave
• Areas 1; 2; 3 = C (4 CO) / S2 (2 S0) / S6 (6 S0) / PR (1 PRI) / BD (4 DID-Pulse/DTMF)
/ MD (4 DID-MFC) / EM (4 E&M) / EL (1 E1) / E1 (8 EXT1) / E2 (8 EXT2) / A1
(16 SLT1) / A2 (16 SLT2)
(Master system only: PR, EL)
Default
KX-TD816: C;E
KX-TD1232: Master and Slave – C;E1;E2
Programming
KX-TD816
1.
Enter 109.
Display: 109 EXPAND C,E1
2.
Press NEXT.
Display example: Master:C ;E
3.
Keep pressing SELECT until the desired selection in Area 1 is displayed.
4.
Press
5.
Keep pressing SELECT until the desired selection in the Area 2 is displayed.
6.
Press STORE.
7.
Press END.
KX-TD1232
1.
Enter 109.
Display: 109 EXPAND C,E1
2.
Press NEXT to programme the Master System.
General Programming
to programme Area 2, if required.
2.2 System Programming
67