Appendix C. I nstallation Instructions
SYSTEM/32 INSTALLATION AND
CONFIGURATION
The following procedure is a guide for installing
the IBM System/32. For basic system installation,
only one person is required and no special tools are
necessi;lry. If you are installing a system with an
integrated modem, a db meter (P/N 453545),
db adapter (P/N 1749299), or equivalent, is
required.
Type of Input
Control Voltage
Transformer
TB1.&
Tap Setting
100 Vac 50 Hz
TB1-1
110Vac50Hz
TBl-2
123.5 Vac 50 Hz
TBl-3
200 Vac 50 Hz
TBl-4
220 Vac 50 Hz
TBl-5
235 Vac 50 Hz
TBl-6
Seria I Printer Trilevel
Supply Transformer
TBE
II
Tap Setting}
(high frequency power
supply only)
Power Supply
II
Ferro Transformer
AC Board
m
to Autotransformer
III
Tap Setting 2
This system was tested and working pro-
perly when shipped. All voltages were ad-
justed and no further adjustments are neces-
sary while installing.
100Vac60Hz2--~----T~B-l-~1------~~~~~~~~~~~~~~--~~-+~~~~~~~~
Check off each step as it is performed.
Be sure to report any problems encountered
using the appropriate major, minor and cause
codes on your I R.
Make safety a habit. Notice the safety rules
listed on page x.
o
o
o
If system is crated, follow the unpacking
instructions attached to the crate.
Remove all shipping braces as described in
the unpacking instructions (attached to the
system).
Locate the power rating and serial number
plate
a.
Make sure the customer's power
and power receptacle are installed and grounded
correctly (verify by asking customer) and they
match the system requirements. If they are
installed correctly but do not match, wire the
machine according to the chart below.
""
200 Vac 60 Hz
TBl-3
208 Vac 60 Hz
TBl-3
230 Vac 60 Hz
TBl-4
} Two leads with yellow tape.
2World Trade only.
"
"
""
""
"
,.
"
"
","
"
"
"
"" "
"
""
./
"" ""
""
""
""
Ferroresonant Power Supply
"
./
"
""
""
""
"" ""
./
""
""
I
I
I
,
I
I
I
I
I
I
I
I
/
I
I
I
g-bJ
~I
,
\
High Frequency Power Supply
~[HIEHlB
1m
\.
, ,
, ,
,
"
,
"
"
I nstallation Instructions
C-1