Print Unit Stop Screw (285 Ipm) - IBM System/32 Introduction And Maintenance Manual

Table of Contents

Advertisement

4.6.10.1 Print Unit Stop Screw (285 Ipm)
Machines with stop screw
a .
Service Check
1.
.open the cover and close the print unit.
2.
Move the forms thickness control to 1.
3.
Check for 0.002 inch to 0.005 inch (0.05
mm to 0.13 mm) at
II.
Adjustment
Loosen the locknut and adjust screw
rl
for 0.002
inch to 0.005 inch (0.05 mm to 0.13 mm).
U=: __
~_II
0.002 inch to 0.005 inch
(0.05 mm to 0.13 mm)
Forms Thickness
Control on 1
4-108