6.4.3. RF Test Jig (Part No. 3WZ001141AAA)
The RF Test Jig provides the connections between the test and the phone for unit testing.
It also provides power supply for the phone. The following spares item is available for the RF Test Jig.
8
RF Probe (Part No. : MS156HRMJ3)
6.4.4. Power Cable (Part No. 3WZ001130AAA)
The power cable provides the necessary connections between the PCB repair jig / dummy battery and external power supply.
6.4.5. USB Data Cable Kit (Part No. WY80023A)
The data cable is used for software download and calibration.
6.4.6. Calibrated Torque Screwdriver
This screwdriver is required to secure the case screws on the phone. It must have settings for 1.3kgf and 2.5kgf.

6.4.7. Power Supply

Two power supplies is required to provide power to the PCB via the PCB Repair Jig while a second unit is required to
provide power baseband calibration and unit testing.
6.4.8. GSM Test Set
This unit acts as a base station providing all the necessary GSM signalling requirements and also provides GSM signal
measuring facilities.
PROVISIONAL ISSUE
Figure 5.2: RF Test jig
Figure 5.3: Power Cable
Figure 5.4: USB Data Cable
– 6-3 –