SERIAL PORT SETUP

On the ADMINISTRATOR SETUP PAGE, click the SERIAL PORT button to display the SERIAL PORT SETUP window.
Specify whether to use the RS-232C or RS-485 interface, and set the communication parameters.
Make certain that the DIP switch #4 on the rear of the transmitter is set to OFF when the RS-485 port is used, or to ON when the
RS-232C port is used.
q TYPE
Specify a peripheral device that communicates with the
transmitter through the serial port. Click the
repeatedly to scroll down the options shown below.
The default setting is PS
The following options are available when DIP switch #4 is
set to OFF (RS-485 ) on the rear of the WJ-NT204.
WJ-SX550A/B: Matrix Switcher System
WJ-FS616: Video Multiplexer
PS . Data: Products capable of Panasonic Security Data
protocol
Serial Through: Data is transmitted through the DATA
port using comthr.html.
The following options are available when DIP switch #4 is
set to ON (RS-232C ) on the rear of the WJ-NT204.
WJ-SX550A/B: Matrix Switcher System
WJ-SX850: System 850 Matrix Switcher
WJ-DR200: Digital Disc Recorder
Serial Through: Data is transmitted through the DATA
port using comthr.html.
w BAUD RATE
Set the rate to 4 800, 9 600 or 19 200 bps. The default
setting is 9 600 bps.
e DATA BIT
Set the data bit to 7 or 8 bits. The default is 8 bits.
r STOP BIT
Set the stop bit to 1 or 2 bits. The default is 1 bit.
t PARITY
Set the parity check to NONE, ODD or EVEN. The
default setting is NONE.
y WAIT TIME
Set the wait time with the
86
button
Data.
button. The default setting
is OFF.
u UNIT ADDRESS
Set an address number within 002 through 999 when
TYPE is set to PS
Data. The default setting is 002.
Notes: Special caution should be used for setting unit
address when the System Controller WV-CU360 is
installed in the system.
• The transmitter WJ-NT204 will be set to address
"1" automatically, when no receiver WJ-NT204 is
connected to the transmitter except the PC. The
WV-CU360 connected to the transmitter should be
set to other than "1".
• The transmitter WJ-NT204 will be set to the
address by this operation, when a receiver WJ-
NT204 is connected. The Control site WV-CU360
connected to the receiver should be set to "1"
while the Remote site WV-CU360 be set to other
than "1" and " transmitter's address".
i GROUP ADDRESS
Set an address within 00A through 00Z. The default
setting is 00A.
o PS . Data Unit Address SETUP
Is linked to the PS . Data Unit Address SETUP page.
!0 WJ-DR200 SETUP
Set the CONTROL PRIORITY from among three
options. The default setting is AUTOMATICALLY
CHANGE OVER.
!1 WJ-SX550A/B and WJ-SX850 MATRIX SWITCHER
SETUP
Clicking on this line will open the WJ-SX550A/B and
WJ-SX850 MATRIX SWITCHER setup window.
q
w
e
r
t
y
u
i
o
!0
!1