WJ-NT204 Setup

First, it is necessary to set an IP address for the WJ-NT204 according to the operating environment. Consult your network
administrator for the address to set.
IP Address Setting via LAN Connection
1. On the Location bar, enter http://192.168.0.10/hwset-
up.html to display the ADMINISTRATOR SETUP
PAGE.
To open the ADMINISTRATOR SETUP PAGE, you
need to enter your user ID and password.
The default ID and password are [admin] and [any
character], respectively.
Click the [NETWORK] button to display the NETWORK
SETUP dialog box.
2. Set IP-ADDRESS, NETMASK, DEFAULT GATEWAY.
Consult your network administrator for the correct set-
tings.
3. Specify the TCP/IP settings for the PC.
If the PC is already operating on a network, specify its
original IP address in the TCP/IP Properties dialog box
(before changing it to 192.168.0.9).
IP Address Setting via RS-232C Connection
1. Connect the serial port (D-Sub 9 pin) on your PC to RS-
232C front port (D-Sub 9 pin) on the WJ-NT204 with a
crossover type cable.
The default settings for communication parameters are:
speed=9600 bps, data length=8 bits, parity=none and
stop bit=1 bit.
2. Start up a terminal software such as HyperTerminal or
the like.
3. Hold down CTRL and D keys simultaneously to enter
the terminal mode.
69
If the PC is running WindowsMe, select
Control Panel
Network
[Properties] button to open the TCP/IP Properties dia-
log box, and enter the IP address.
Refer to the settings on page 67.
4. Restart the PC.
5. Start the PC's browser.
Specify http://(IP address set in the WJ-NT204)/ in the
Location bar. The connection is established when the
image from the WJ-NT204 is displayed on the PC
screen.
Note: Refer page 68 for further details.
4. Press ENTER when the password inquiry appears.
5. Type "dispon" from the keyboard following the prompt
(>) on the display, then press ENTER.
6. Hold down CTRL and R keys simultaneously to enter
the menu operation mode.
7. Operate the keyboard following the guidance shown by
the terminal software.
8. To escape from the terminal mode, hold down CTRL
and R, then CTRL and D, otherwise the Remote
Controller WV-CU20 will not function.
Configuration, click the