400 SETUP
Eight of fundamentals are set up for the system.
The menus 430, 460 and 470 will be replaced with dashed
lines when the unit is set to a receiver.
400 SETUP
410 RE-CONNECTION
420 SERIAL/HOST PORT
430 VIDEO SWITCH SETUP
440 AUDIO
450 VIDEO
460 ALARM
470 SEQ.SCAN SETUP
480 LOCK/MENU PASSWORD
:MOVE ENT:SELECT ESC:PRV
1. The 400 SETUP menu appears when you press the
ENTER button after selecting it in the 000 TOP menu.
2. Select a menu you wish to set up from the 410, 420,
430, 440, 450, 460, 470, and 480, then press the
ENTER. The selected menu appears.
410 RE-CONNECTION
Re-connection is started by the site that is set to ON for this
setting when a call is interrupted during communication.
This setting is applicable only to the system comprising two
WJ-NT204 units, one for TRANSMITTER and the other for
RECEIVER, and when the call has been made with the
Remote Controller WV-CU20. This does not perform in the
multi-site connection.
410 RE-CONNECTION
RE-CONNECTION : ON
IN COM.STATE,NT204 WILL CONNECT
AGAIN IN CASE OF NETWORK
INTERRUPTION.
:SELECT ESC:PRV
1. Open the 410 RE-CONNECTION menu.
2. Select either ON or OFF with the direction button. The
default setting is ON.
ON: Re-connection is enabled.
OFF: Disabled.
40
OFF
420 SERIAL/HOST PORT
Serial and Host ports are set up in this menu.
420 SERIAL/HOST PORT
421 SERIAL DATA PORT
422 HOST PORT
:MOVE ENT:SELECT ESC:PRV
1. Open the 420 SERIAL/HOST PORT menu.
2. Select a menu you wish to set up from the 421 and 422,
then press the ENTER. The selected menu appears.
421 SERIAL DATA PORT: Select this when the system
comprises a Matrix Switcher (WJ-SX550A/B),
Digital Disk Recorder or other PS
422 HOST PORT: Select this when the system con-
nects with a personal computer.
421 SERIAL DATA PORT
The DIP switch #4 on the rear of the unit specifies the
usable serial port from RS-232C or RS-485 (PS
settings below must be the same among the devices con-
nected in the chain, except the unit #.
421 SERIAL DATA PORT
RATE
:
4800
DATA BITS:
8
STOP BITS:
1
PARITY
:
NONE
MODE : PSD
NORMAL
RS485
UNIT
#:002
:MOVE
:SELECT ESC:PRV
1. Open the 421 SERIAL DATA PORT menu.
2. Move the cursor to RATE, then select a Baud rate with
the A or B button.
The default setting is 9600.
4800: 4800 bps (bit per second)
9600: 9600 bps
19200: 19200 bps
Data devices.
•
Data). The
•
9600
19200
7
2
ODD
EVEN
(002-999)