Setup; Re-Connection; Serial/Host Port - Panasonic WJ-NT204 Operating Instructions Manual

Network interface unit
Hide thumbs Also See for WJ-NT204:
Table of Contents

Advertisement

400 SETUP

Eight of fundamentals are set up for the system.
The menus 430, 460 and 470 will be replaced with dashed
lines when the unit is set to a receiver.
400 SETUP

410 RE-CONNECTION

420 SERIAL/HOST PORT

430 VIDEO SWITCH SETUP
440 AUDIO
450 VIDEO
460 ALARM
470 SEQ.SCAN SETUP
480 LOCK/MENU PASSWORD
:MOVE ENT:SELECT ESC:PRV
1. The 400 SETUP menu appears when you press the
ENTER button after selecting it in the 000 TOP menu.
2. Select a menu you wish to set up from the 410, 420,
430, 440, 450, 460, 470, and 480, then press the
ENTER. The selected menu appears.
410 RE-CONNECTION
Re-connection is started by the site that is set to ON for this
setting when a call is interrupted during communication.
This setting is applicable only to the system comprising two
WJ-NT204 units, one for TRANSMITTER and the other for
RECEIVER, and when the call has been made with the
Remote Controller WV-CU20. This does not perform in the
multi-site connection.
410 RE-CONNECTION
RE-CONNECTION : ON
IN COM.STATE,NT204 WILL CONNECT
AGAIN IN CASE OF NETWORK
INTERRUPTION.
:SELECT ESC:PRV
1. Open the 410 RE-CONNECTION menu.
2. Select either ON or OFF with the direction button. The
default setting is ON.
ON: Re-connection is enabled.
OFF: Disabled.
40
OFF
420 SERIAL/HOST PORT
Serial and Host ports are set up in this menu.
420 SERIAL/HOST PORT
421 SERIAL DATA PORT
422 HOST PORT
:MOVE ENT:SELECT ESC:PRV
1. Open the 420 SERIAL/HOST PORT menu.
2. Select a menu you wish to set up from the 421 and 422,
then press the ENTER. The selected menu appears.
421 SERIAL DATA PORT: Select this when the system
comprises a Matrix Switcher (WJ-SX550A/B),
Digital Disk Recorder or other PS
422 HOST PORT: Select this when the system con-
nects with a personal computer.
421 SERIAL DATA PORT
The DIP switch #4 on the rear of the unit specifies the
usable serial port from RS-232C or RS-485 (PS
settings below must be the same among the devices con-
nected in the chain, except the unit #.
421 SERIAL DATA PORT
RATE
:
4800
DATA BITS:
8
STOP BITS:
1
PARITY
:
NONE
MODE : PSD
NORMAL
RS485
UNIT
#:002
:MOVE
:SELECT ESC:PRV
1. Open the 421 SERIAL DATA PORT menu.
2. Move the cursor to RATE, then select a Baud rate with
the A or B button.
The default setting is 9600.
4800: 4800 bps (bit per second)
9600: 9600 bps
19200: 19200 bps
Data devices.
Data). The
9600
19200
7
2
ODD
EVEN
(002-999)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wv-cu20