2.3 Alarm Connection

2.3.1

Alarm Port

The alarm port is shown as below. See Figure 2-3.
Icon
1~4
N1,N2,C1,C2
A/B
2.3.2

Alarm input port

Connect the positive end (+) of the alarm input device to the alarm input port (ALARM IN 1~4) of the
NVR. Connect the negative end (-) of the alarm input device to the ground end ( ) of the NVR.
Note
When connect the ground port of the alarm device to the NVR, you can use any of the GND ports
(
).
Connect the C port of the alarm device to the alarm input port (ALARM) of the NVR.
When there is peripheral power supplying for the alarm device, please make sure it is earthed with
the NVR.
2.3.3

Alarm input and output port

There is peripheral power supplying for the external alarm device.
In case overload may result in NVR damage, please refer to the following relay specifications for
detailed information.
A/B cable of the RS485 is for the A/B cable connection of the speed PTZ.
Figure 2-3
Function
ALARM1~ALARM4. The alarm becomes activated in the
low level.
Two N activation output groups. (On-off button)
GND
485 communication port. They are used to control devices
such as PTZ. Please parallel connect 120TΩ between A/B
cables if there are too many PTZ decoders.