452 ON_SCREEN DISPLAY
You can set the display contents in this menu.
452 ON-SCREEN DISPLAY
VIDEO INPUT DISP.:
TITLE DISP.
CLOCK DISP.
:MOVE
1. Open the 452 ON_SCREEN DISPLAY menu.
2. Move the cursor to VIDEO INPUT DISP. and select ON
or OFF with the A or B button. The default setting is
ON.
ON: Enables the display of the currently designated
video input.
OFF: Disables the display.
3. Move the cursor to TITLE DISP. and select ON or OFF
with the A or B button. The default setting is ON.
ON: Enables the title display.
OFF: Disables the display.
4. Move the cursor to CLOCK DISP. and select ON or
OFF with the A or B button. The default setting is ON.
ON: Enables the time and date display.
OFF: Disables the display.
453 CABLE COMPENSATION (Transmitter only)
Picture quality is lowered as long as the cable is extended
between the transmitter and the camera. Compensation is
applied to the transmitter in three degrees with assumption
that RG-59/U, BELDEN 9259 or equivalent cable is used.
The default setting is S.
453 CABLE COMPENSATION
CAMERA1:
CAMERA2:
CAMERA3:
CAMERA4:
:MOVE
1. Open the 453 CABLE COMPENSATION menu.
2. Move the cursor to CAMERA 1 and select S, M or L
with the A or B button.
43
ON
OFF
:
ON
OFF
:
ON
OFF
:SELECT ESC:PRV
S
M
L
S
M
L
S
M
L
S
M
L
:SELECT ESC:PRV
S (Short): Up to 400 m (1 300 ft)
M (Middle): From 400 m (1 300 ft) to 700 m (2 300 ft)
L (Long): From 700 m (2 300 ft) to 900 m (3 000 ft)
3. Repeat above step for the remaining cameras.
460 ALARM (Transmitter only)
Alarm sensors are connected with a transmitter unit, and
are located at where the camera aims or associated
places. If a connected sensor operates, the transmitter unit
will notify the Control site of the alarm activation during
standby mode. Then the unit starts communication to trans-
mit image and audio. The 460 ALARM menu lets you select
and set up the 461 ALARM SETUP, 462 to 464 ALARM
DIALING TABLES and 465 ALARM PORT SETUP. For more
information, see SENSOR OPERATION in APPENDIX.
1. Open the 460 ALARM menu.

460 ALARM

461 ALARM SETUP
462 ALARM DIALING TABLE1
463 ALARM DIALING TABLE2
464 ALARM DIALING TABLE3
465 ALARM PORT SETUP
:MOVE ENT:SELECT ESC:PRV
2. Select 461, 462, 463, 464 or 465 with the D or C but-
ton, then press the ENTER.
The selected menu appears.
Transmitter only)
461 ALARM SETUP (
This setup is applied only to the transmitter.
1. Open the 461 ALARM SETUP menu.
461 ALARM SETUP
ALARM TYPE:
LEVEL
ALARM AUTO DISC
ALARM AUTO DISC TIMER :
ALARM DIALING TIME TABLE:
TABLE
DAY
1
MON-SUN
2
MON-FRI
3
FRI-MON
ENT:DAY INC. DEL:CLR
:MOVE ESC:PRV
2. Move the cursor to ALARM TYPE and select either
LEVEL or EDGE (OPEN CLOSE) with the A or B but-
ton. The default setting is EDGE (CLOSE).
EDGE(OPEN CLOSE)
:
ON OFF
060S
TIME
00:00-00:00
08:30-17:00
17:00-08:00

Advertisement