Product Certifications
August 2016
B.2 Rosemount 3051 Wireless
Pressure Transmitter
Rev 1.2
B.2.1 European Directive Information
A copy of the EC Declaration of Conformity can be found at
the end of the Quick Start Guide. The most recent revision
of the EC Declaration of Conformity can be found at
EmersonProcess.com/Rosemount.
B.2.2 Telecommunication Compliance
All wireless devices require certification to ensure that they
adhere to regulations regarding the use of the RF spectrum.
Nearly every country requires this type of product
certification.
Emerson is working with governmental agencies around
the world to supply fully compliant products and remove
the risk of violating country directives or laws governing
wireless device usage.
B.2.3 FCC and IC
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following conditions: This device
may not cause harmful interference. This device must
accept any interference received, including interference
that may cause undesired operation. This device must be
installed to ensure a minimum antenna separation distance
of 20 cm from all persons.
B.2.4 Ordinary Location Certification for FM
The US National Electrical Code (NEC) and the Canadian
Electrical Code (CEC) permit the use of Division marked
equipment in Zones and Zone marked equipment in
Divisions. The markings must be suitable for the area
classification, gas, and temperature class. This information
is clearly defined in the respective codes.
B.2.5 U.S.A.
I5
U.S.A. Intrinsically Safe (IS)
Certificate: FM 3046325
Standards: FM Class 3600 - 2011,
FM Class 3610 - 2010,
FM Class 3810 - 2005,
ANSI/ISA 60079-0 - 2009,
ANSI/ISA 60079-11 - 2009,
NEMA 250 - 2003, ANSI/IEC 60529
Markings: IS CL I, DIV 1, GP A, B, C, D T4; CL 1, Zone 0
AEx ia IIC T4; T4(-40 °C ≤ T
when installed per Rosemount drawing
03031-1062; Type 4X/IP66/IP68

146

Special Conditions for Safe Use (X):
1. The Rosemount 3051 Wireless Pressure Transmitter
shall only be used with the 701PGNKF Rosemount
SmartPower
2. The in-line pressure sensor may contain more than
10% aluminum and is considered a potential risk of
ignition by impact or friction. Care must be taken into
account during installation and used to prevent
impact and friction.
3. The surface resistivity of the transmitter housing is
greater than one gigaohm. To avoid electrostatic
charge build-up, it must not be rubbed or cleaned
with solvents or a dry cloth.
B.2.6 Canada
I6
Canada Intrinsically Safe
Certificate: CSA 2526009
Standards: CAN/CSA C22.2 No. 0-M91,
Markings: Intrinsically Safe for Class I, Division 1,
B.2.7 Europe
I1
ATEX Intrinsic Safety
Certificate: Baseefa12ATEX0228X
Standards: EN60079-11:2012, EN60079-0:2012
Markings:
Special Conditions for Safe Use (X):
1. The plastic enclosure may constitute a potential
electrostatic ignition risk and must not be rubbed or
cleaned with a dry cloth.
2. The Model 701PGNKF Power Module may be replaced
in a hazardous area. The power module has a surface
resistivity greater than 1GΩ and must be properly
installed in the wireless device enclosure. Care must
be taken during transportation to and from the point
of installation to prevent electrostatic charge
build-up.
≤ +70 °C)
a
Reference Manual
00809-0100-4797, Rev DA
Battery Pack.
CAN/CSA C22.2 No. 94-M91,
CSA Std C22.2 No. 142-M1987,
CSA Std C22.2 No. 157-92,
CSA Std C22.2 No. 60529:05
Groups A, B, C, D, T4 when installed per
Rosemount drawing 03031-1063;
Type 4X/IP66/IP68
II 1 G Ex ia IIC T4 Ga,
T4(-40 °C ≤ T
≤ +70°C)
a
IP66/IP68