Appendix B
Rosemount
Rosemount 3051 Wireless Pressure Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 146
Approval drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 148
B.1 Rosemount
Transmitter
Rev 1.2
B.1.1 European Directive Information
A copy of the EC Declaration of Conformity can be found at
the end of the Quick Start Guide. The most recent revision
of the EC Declaration of Conformity can be found at
EmersonProcess.com/Rosemount.
B.1.2 Ordinary Location Certification
As standard, the transmitter has been examined and tested
to determine that the design meets the basic electrical,
mechanical, and fire protection requirements by a
nationally recognized test laboratory (NRTL) as accredited
by the Federal Occupational Safety and Health
Administration (OSHA).
B.1.3 North America
E5
USA Explosionproof (XP) and Dust-Ignitionproof (DIP)
Certificate: 0T2H0.AE
Standards: FM Class 3600 – 2011,
FM Class 3615 – 2006,
FM Class 3810 – 2005,
ANSI/NEMA
Markings: XP CL I, DIV 1, GP B, C, D; DIP CL II, DIV 1,
GP E, F, G; CL III; T5(-50 °C
Factory Sealed; Type 4X
I5
USA Intrinsic Safety (IS) and Nonincendive (NI)
Certificate: 1Q4A4.AX
Standards: FM Class 3600 – 2011,
FM Class 3610 – 2010,
FM Class 3611 – 2004,
FM Class 3810 – 2005
Markings: IS CL I, DIV 1, GP A, B, C, D;
CL II, DIV 1, GP E, F, G; Class III;
DIV 1 when connected per Rosemount
drawing 03031-1019;
NI CL 1, DIV 2, GP A, B, C, D;
T4(-50 °C
T5(-50 °C
T4(-50 °C
[Fieldbus/PROFIBUS
Product Certifications
Product Certifications
3051 Pressure Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 139
3051 Pressure
®
250 – 2003
T
+85 °C);
a
®
T
+70 °C) [HART
],
a
T
+40 °C) [HART];
a
T
+60 °C)
a
®
]; Type 4x
Special Conditions for Safe Use (X):
1. The Rosemount 3051 Transmitter housing contains
aluminum and is considered a potential risk of ignition
by impact or friction. Care must be taken into account
during installation and use to prevent impact and
friction.
2. The Rosemount 3051 Transmitter with the transient
terminal block (Option code T1) will not pass the
500 Vrms dielectric strength test and this must be
taken into account during installation.
IE
USA FISCO
Certificate: 1Q4A4.AX
Standards: FM Class 3600 – 2011,
FM Class 3610 – 2010,
FM Class 3611 – 2004,
FM Class 3810 – 2005
Markings: IS CL I, DIV 1, GP A, B, C, D when
connected per Rosemount drawing
03031-1019 (-50 °C
Special Conditions for Safe Use (X):
1. The Rosemount 3051 Transmitter housing contains
aluminum and is considered a potential risk of ignition
by impact or friction. Care must be taken into account
during installation and use to prevent impact and
friction.
2. The Rosemount 3051 Transmitter with the transient
terminal block (Option code T1) will not pass the
500 Vrms dielectric strength test and this must be
taken into account during installation.
C6
Canada Explosionproof, Dust-Ignitionproof, Intrinsic
Safety and Nonincendive
Certificate: 1053834
Standards: ANSI/ISA 12.27.01-2003,
CSA Std. C22.2 No. 30 -M1986,
CSA Std. C22.2 No.142-M1987,
CSA Std. C22.2. No.157-92,
CSA Std. C22.2 No. 213 - M1987
Markings: Explosionproof for Class I, Division 1,
Groups B, C and D; Suitable for Class I,
Zone 1, Group IIB+H2, T5;
Dust-Ignitionproof Class II, Division 1,
Groups E, F, G; Class III Division 1;
Intrinsically Safe Class I, Division 1 Groups
A, B, C, D when connected in accordance
with Rosemount drawing 03031-1024,
Product Certifications
August 2016
T
+60 °C); Type 4x