Emerson Rosemount 3051 Reference Manual page 110

Pressure transmitter with profibus pa protocol
Hide thumbs Also See for Rosemount 3051:
Table of Contents

Advertisement

Specifications and Reference Data
August 2016
Table A-15. Rosemount 3051CFC Compact Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
The Expanded offering is subject to additional delivery lead time.
Configuration buttons
(15)
D4
Analog zero and span
(25)
DZ
Digital zero trim
Typical model number: 3051CFC D C S 060 N 065 0 3 2 A A 1 WC E5 M5
1.
Select configuration buttons (option code D4 or DZ) or LOI (option code M4) if local configuration buttons are required.
2.
Available with Primary Element Technology P only.
3.
10-in. (250 mm) and 12-in. (300 mm) line sizes not available with Primary Element Technology A.
4.
For 2-in. (50 mm) line sizes the Primary Element Type is 0.6 for Primary Element Technology code C.
5.
Option HR5 configures the HART output to HART Revision 5. Option HR7 configures the HART output to HART Revision 7. The device can be field
configured to HART Revision 5 or 7 if desired. HART Revision 5 is the default HART output.
6.
For local addressing and configuration, M4 (LOI) is required.
7.
Requires wireless options and engineered polymer housing. Available approvals are FM Intrinsically Safe, (option code I5), CSA Intrinsically Safe
(option code I6), ATEX Intrinsic Safety (option code I1), and IECEx Intrinsic Safety (option code I7).
8.
Only available with C6, E2, E5, I5, K5, KB and E8 approval. Not available with GE, GM, SBS, DA0, M4, D4, DZ, QT, HR5, HR7, CR, CS, CT.
9.
Only available with Wireless output (output code X).
10. Not available with Product certifications options E8, K8, E5, K5, C6, K6, E7, K7, E2, K2, E3, KB, KD.
11. Transmitter conduit entry will be
12. Available with Primary Element Technology C only.
13. For Annubar option A, consult factory for pipe schedules other than schedule 40.
14. Available with Primary Element Technology C or P only.
15. Only available with HART 4-20 mA Output (output code A).
16. Materials of Construction comply with metallurgical requirements within NACE MR0175/ISO for sour oil field production environments.
Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining
environments.
17. Dust approval not applicable to output code X. See
18. Nonincendive certification not provided with Wireless output option code (X).
19. Not available with Wireless output (output code X).
20. Only available with product certifications E7, E8, I1, I7, IA, K7, K8, KD, N1, N7
21. Not available with output code F - F
22. The T1 option is not needed with FISCO product certifications, transient protection is included with the FISCO product certification code IA, IB, and IE.
23. Only valid with F
OUNDATION
24. The V5 option is not needed with the T1 option; external ground screw assembly is included with the T1 option.
25. Only available with 4-20 mA HART Output (output code A) and Wireless output (output code X).
100
1
1
1
/
2
NPT and a
/
2
NPT to G
/
2
"Rosemount 3051 Wireless Pressure Transmitter" on page 146
Fieldbus or Wireless output (output code X) or Low Power (output code M).
OUNDATION
Fieldbus (output code F).
thread adapter will be provided.
Reference Manual
00809-0100-4797, Rev DA
for wireless approvals
Specifications and Reference Data

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents