Emerson Rosemount 3051 Reference Manual page 94

Pressure transmitter with profibus pa protocol
Hide thumbs Also See for Rosemount 3051:
Table of Contents

Advertisement

Specifications and Reference Data
August 2016
Table A-13. Rosemount 3051T In-Line Pressure Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
The Expanded offering is subject to additional delivery lead time.
Pressure testing
P1
Hydrostatic testing with certificate
Cleaning process area
P2
Cleaning for special service
P3
Cleaning for <1 PPM Chlorine/Fluorine
(9)(29)
Ground screw
V5
External ground screw assembly
Surface finish
Q16
Surface finish certification for sanitary remote seals
Toolkit total system performance reports
QZ
Remote seal system performance calculation report
Conduit electrical connector
GE
M12, 4-pin, male connector (eurofast)
GM
A size mini, 4-pin, male connector (minifast)
(30)
NACE certificate
Q15
Certificate of Compliance to NACE MR0175/ISO15156 for wetted materials
Q25
Certificate of Compliance to NACE MR0103 for wetted materials
Typical model number: 3051T G 5 F 2A 2 1 A B4
1.
Select Configuration Buttons (option code D4 or DZ) or Local Operator Interface (option code M4) if local configuration buttons are required.
2.
Wireless output (code X) only available in absolute measurement type (code A) in range 1-5 with
polymer housing (code P).
3.
Rosemount 3051TG lower range limit varies with atmospheric pressure.
4.
Option HR5 configures the HART output to HART Revision 5. Option HR7 configures the HART output to HART Revision 7. The device can be field
configured to HART Revision 5 or 7 if desired. HART Revision 5 is the default HART output.
5.
For local addressing and configuration, M4 (LOI) is required.
6.
Requires wireless options and engineered polymer housing. Available approvals are FM Intrinsically Safe, (option code I5), CSA Intrinsically Safe
(option code I6), ATEX Intrinsic Safety (option code I1), IECEx Intrinsic Safety (option code I7), and EAC Intrinsic Safety (option code IM).
7.
Only available with C6, E2, E5, I5, K5, KB and E8 product certifications. Not available with GE, GM, SBS, DA0, M4, D4, DZ, QT, HR5, HR7, CR, CS, CT.
8.
Wireless output (code X) only available in G
(code 2), silicone fill fluid (code 1) and housing code (code P).
9.
Not available with Wireless Output (output code X).
10. Materials of Construction comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments. Environmental
limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
11. Only available with Wireless Output (output code X).
12. Not available with product certifications options E8, K8, E5, K5, C6, K6, E7, K7, E2, K2, E3, KB, KD.
13. Transmitter conduit entry will be
14. Only valid with F
OUNDATION
15. "Assemble-to" items are specified separately and require a completed model number.
16. Panel mounting bolts are not supplied.
17. Dust approval not applicable to output code X. See
18. Only available with output codes A - 4-20mA HART, F - F
19. Nonincendive certification not provided with Wireless output option code (X).
84
(28)
(9)
1
/
A DIN 16288 Male process connection (code 2C) with range 1-4, 316 SST isolating diaphragm
2
1
1
1
/
2
NPT and a
/
2
NPT to G
/
2
Fieldbus output code F.
"Rosemount 3051 Wireless Pressure Transmitter" on page 146
OUNDATION
thread adapter will be provided.
Fieldbus, and W - PROFIBUS PA. Also only available with G
Reference Manual
00809-0100-4797, Rev DA
1
/
–14 NPT process connection (code 2B), and
2
for wireless approvals.
1
/
housing thread types.
2
Specifications and Reference Data

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents