Emerson Rosemount 3051 Reference Manual page 103

Pressure transmitter with profibus pa protocol
Hide thumbs Also See for Rosemount 3051:
Table of Contents

Advertisement

Reference Manual
00809-0100-4797, Rev DA
Table A-14. Rosemount 3051CFA Annubar Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
The Expanded offering is subject to additional delivery lead time.
Transmitter calibration certification
Q4
Calibration certificate for transmitter
Quality certification for safety
QS
Prior-use certificate of FMEDA data
QT
Safety certified to IEC 61508 with certificate of FMEDA
Transient protection
(19)
T1
Transient terminal block
Manifold for remote mount option
F2
3-valve manifold, stainless steel
F6
5-valve manifold, stainless steel
F1
3-valve manifold, carbon steel
F3
3-valve manifold, Alloy C-276
F5
5-valve manifold, carbon steel
F7
5-valve manifold, Alloy C-276
Lower power output
C2
0.8-3.2 Vdc output with digital signal based on HART Protocol (available with output code M only)
Alarm levels
(16)
C4
NAMUR alarm and saturation levels, high alarm
CN
NAMUR alarm and saturation levels, low alarm
CR
Custom alarm and saturation signal levels, high alarm
CS
Custom alarm and saturation signal levels, low alarm
CT
Rosemount standard low alarm
Configuration buttons
(16)
D4
Analog zero and span
(23)
DZ
Digital zero trim
(24)
Ground screw
(19)
V5
External ground screw assembly
Typical model number: 3051CFA D L 060 D C H P S 2 T1 0 0 0 3 2 A A 1
1.
Select configuration buttons (option code D4 or DZ) or LOI (option code M4) if local configuration buttons are required.
2.
Available in remote mount applications only.
3.
The cage nipple is constructed of 304 SST.
4.
Option HR5 configures the HART output to HART Revision 5. Option HR7 configures the HART output to HART Revision 7. The device can be field
configured to HART Revision 5 or 7 if desired. HART Revision 5 is the default HART output.
5.
For local addressing and configuration, M4 (Local Operator Interface) is required.
6.
Requires wireless options and engineered polymer housing. Available approvals are FM Intrinsically Safe, (option code I5), CSA Intrinsically Safe
(option code I6), ATEX Intrinsic Safety (option code I1), and IECEx Intrinsic Safety (option code I7).
Specifications and Reference Data
(16)
(22)
Specifications and Reference Data
August 2016
93