Specifications and Reference Data
August 2016
Table A-17. Rosemount 3051L Level Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (H) should be selected for best delivery.
The Expanded offering is subject to additional delivery lead time.
(7)(22)
Ground screw
V5
External ground screw assembly
Lower housing flushing connection options
Ring material
F1
316 SST
F2
316 SST
F3
Alloy C-276
F4
Alloy C-276
F7
316 SST
F8
316 SST
F9
Alloy C-276
F0
Alloy C-276
Lower housing intermediate gasket material
S0
No gasket for lower housing
(23)
SY
Thermo-Tork TN-9000
(24)
NACE certificate
Q15
Certificate of compliance to NACE MR0175/ISO 15156 for wetted materials
Q25
Certificate of compliance to NACE MR0103 for wetted materials
Typical model number: 3051L 2 A A0 D 21 A A F1
1.
Select configuration buttons (option code D4 or DZ) or LOI (option code M4) if local configuration buttons are required.
2.
Option HR5 configures the HART output to HART Revision 5. Option HR7 configures the HART output to HART Revision 7. The device can be field
configured to HART Revision 5 or 7 if desired. HART Revision 5 is the default HART output.
3.
Option code M4 - LCD display with LOI required for local addressing and configuration.
4.
Requires wireless options and engineered polymer housing. Available approvals are FM Intrinsically Safe, (option code I5), CSA Intrinsically Safe
(option code I6), ATEX Intrinsic Safety (option code I1), IECEx Intrinsic Safety (option code I7) and EAC Intrinsic Safety (option code IM).
5.
Only available with C6, E2, E5, I5, K5, KB and E8 approval. Not available with GE, GM, SBS, DA0, M4, D4, DZ, QT, HR5, HR7, CR, CS, CT.
6.
Materials of construction comply with metallurgical requirements highlighted within NACE MR0175/ISO 15156 for sour oil field production
environments. Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103
for sour refining environments.
7.
Not available with Wireless output (output code X).
8.
Only available with Wireless output (output code X).
9.
Not available with Product certifications options E8, K8, E5, K5, C6, K6, E7, K7, E2, K2, E3, KB, KD.
10. Transmitter conduit entry will be
11. Only valid with F
OUNDATION
12. "Assemble-to" items are specified separately and require a completed model number.
13. Dust approval not applicable to output code X. See
14. Only available with output codes A - 4-20mA HART, F - F
15. Nonincendive certification not provided with Wireless output option code (X).
16. Only available with product certifications E7, E8, I1, I7, IA, K7, K8, KD, N1, N7.
17. Not available with F
OUNDATION
18. Contact an Emerson Process Management representative for availability.
19. Only available with HART 4-20 mA output (output code A).
20. Only available with 4-20 mA HART output (output code A) and Wireless output (output code X).
114
1
1
1
/
2
NPT and a
/
2
NPT to G
/
2
Fieldbus output (output code F).
"Rosemount 3051 Wireless Pressure Transmitter" on page 146
OUNDATION
Fieldbus (output code F) or Wireless output (output code X) or Low Power (output code M).
Number
1
2
1
2
1
2
1
2
thread adapter will be provided.
Fieldbus, and W - PROFIBUS PA. Also only available with G
Reference Manual
00809-0100-4797, Rev DA
Size (NPT)
1
/
–18 NPT
4
1
/
–18 NPT
4
/
–18 NPT
1
4
1
/
–18 NPT
4
/
–14 NPT
1
2
/
–14 NPT
1
2
1
/
–14 NPT
2
/
–14 NPT
1
2
for wireless approvals.
1
/
housing thread types.
2
Specifications and Reference Data