Emerson Rosemount 3051 Reference Manual page 120

Pressure transmitter with profibus pa protocol
Hide thumbs Also See for Rosemount 3051:
Table of Contents

Advertisement

Specifications and Reference Data
August 2016
Table A-17. Rosemount 3051L Level Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (H) should be selected for best delivery.
The Expanded offering is subject to additional delivery lead time.
Seal fill fluid (high side)
D
Silicone 200
Silicone 200 for Vacuum
F
Applications
D.C. Silicone 704 Diffusion
L
Pump Fluid
D.C. Silicone 704 for
C
Vacuum Applications
R
Silicone 705
Silicone 705 for Vacuum
V
Applications
A
SYLTHERM XLT
H
Inert (Halocarbon)
G
Glycerin and water
N
Neobee M-20
P
Propylene glycol and water
Low pressure side
Configuration
(6)
11
Gage
21
Differential
(6)
22
Differential
(7)
2A
Differential
(6)(7)
2B
Differential
Tuned-System Assembly
(6)
31
with remote seal
O-ring
A
Glass-filled PTFE
Housing material
A
Aluminum
B
Aluminum
J
SST
K
SST
(8)
P
Engineered polymer
110
Specific
Temperature limits
gravity
(ambient temperature of 70° F [21° C])
0.93
-49 to 401 °F (-45 to 205 °C)
For use in vacuum applications below 14.7 psia (1 bar-a),
0.93
refer to vapor pressure curves in Rosemount DP Level Fill
Fluid Specifications
1.07
32 to 401 °F (0 to 205 °C)
For use in vacuum applications below 14.7 psia (1 bar-a),
1.07
refer to vapor pressure curves in Rosemount DP Level Fill
Fluid Specifications
1.09
68 to 401 °F (20 to 205 °C)
For use in vacuum applications below 14.7 psia (1 bar-a),
1.09
refer to vapor pressure curves in Rosemount DP Level Fill
Fluid Specifications
0.85
-102 to 293 °F (-75 to 145 °C)
1.85
-49 to 320 °F (-45 to 160 °C)
1.13
5 to 203 °F (-15 to 95 °C)
0.92
5 to 401 °F (-15 to 205 °C)
1.02
5 to 203 F (-15 to 95 °C)
Flange
Diaphragm material
adapter
SST
316L SST
SST
316L SST
SST
Alloy C-276
SST
316L SST
SST
Alloy C-276
None
316L SST
Conduit entry size
1
/
–14 NPT
2
M20
1.5
1
/
–14 NPT
2
M20
1.5
No conduit entries
Reference Manual
00809-0100-4797, Rev DA
Technical
Note.
Technical
Note.
Technical
Note.
Sensor fill fluid
Silicone
Silicone
Silicone
Inert (Halocarbon)
Inert (Halocarbon)
Silicone
(requires option code S1)