WARNING
Gasoline is harmful or fatal if swallowed. Long-term
exposure to vapors can cause serious injury and
illness.
• Avoid prolonged breathing of vapors.
• Keep face away from nozzle and gas tank or
conditioner bottle opening.
• Avoid contact with skin; wash off spillage with
soap and water.
1. Clean the area around the fuel tank cap.
2. Remove the fuel tank cap (Figure 13).
Figure 13
1. Fuel tank cap
3. Fill the tank to about one inch below the top of the
tank, (bottom of the filler neck), then install the cap.
Do not overfill.
4. Wipe up any fuel that may have spilled to prevent a
fire hazard.
Checking the
Transaxle/Hydraulic Fluid
Level
Service Interval: Before each use or daily
The transaxle reservoir is filled with Dexron III ATF. Check
the level before the engine is first started and every 8 hours or
daily, thereafter. Capacity of system is .
Transaxle reservoir capacity: 7.0 L (7.5 qt).
1. Position the machine on a level surface.
2. Clean the area around the dipstick (Figure 14).
1. Dipstick
3. Unscrew the dipstick from the top of the transaxle and
wipe it with a clean rag.
4. Screw the dipstick into the transaxle and ensure that
it is fully seated.
5. Unscrew the dipstick and check the fluid level.
The fluid should be up to top of the flat portion of
the dipstick.
6. If the level is low, add enough fluid to achieve the
proper level.