Figure 18
1. Reserve tank-cap
2. Reserve tank
3. If coolant is low, remove the reserve tank cap and add a
50/50 mixture of water and permanent ethylene-glycol
antifreeze.
Note: Do not overfill the reserve tank with coolant.
4. Install the reserve-tank cap.
Checking the
Transaxle/Hydraulic-fluid
Level
Service Interval: Before each use or daily (check the fluid
level before the engine is first started and
every 8 hours or daily, thereafter.)
Transaxle fluid type: Dexron III ATF
1. Position the machine on a level surface.
2. Clean the area around the dipstick (Figure 19).
1. Dipstick
3. Unscrew the dipstick from the top of the transaxle and
wipe it with a clean rag.
4. Screw the dipstick into the transaxle and ensure that
it is fully seated.
5. Unscrew the dipstick and check the fluid level.
Note: The fluid should be up to top of the flat portion
of the dipstick.
6. If the level is low, add enough of the specified fluid to
achieve the proper level.