Overview of modules
Function expansions with options bus
Contact
1
2
3
4
5
6
7
8
9
10
* in the case of GEE 50 FRA (otherwise not assigned)
Table 3-19
Contact assignment of the GEE module
3.6.3

Serial interface board (SIB) (V.24 connection)

An additional V.24 interface is offered as an optional babyboard in the GEE12/16 module hous-
ing. Level matching and galvanic isolation of the V.24 adapter are implemented on the SIB. The
2400 baud rate cannot be changed.
Up to 4 GEE modules can be installed; up to 4 serial interface boards can therefore be operat-
ed.
to TLA
10
to trunk
MSI
Figure 3-13
SIB (serial interface board) interfaces
3-22
a
GND *
b
Trunk 1 (BN 1)
a
Trunk 1 (AN 1)
b
Trunk 2 (BN 2)
a
Trunk 2 (AN 2)
b
Trunk 3 (BN 3)
a
Trunk 3 (AN 3)
b
Trunk 4 (BN 4)
a
Trunk 4 (AN 4)
Call charging module
assignment
1
GEE module
X3
Connecting
1
cable
X4
8
Port X3
Trunk 1 (AL1)
Trunk 1 (BL1)
Trunk 2 (AL2)
Trunk 2 (BL2)
Trunk 3 (AL3)
Trunk 3 (BL3)
Trunk 4 (AL4)
Trunk 4 (BL4)
X5
Port X4
MB side
SIB
Connecting cable
Module side
to printer/PC
A31003-K16-X001-3-7620
Hicom 100 E Version 2.1, Service manual
Port X5
0V
0V
RTS
CTS
RXD
TXD
0V
+5V
0V
+5V
2 sub-D plugs
(9-pin)
,
07/99