Least Cost Routing (LCR)
Corporate Network LCR (as of V2.0.2)
8.4.1

Examples of corporate networks

Characters selected
(max. 7 digits)
1
04711
2
8765487
3
5465465
4
089722
5
0211
55
6
7
8
50
- Standard or not relevant
In order to allow all calls to be set up via a specific trunk group (e.g. networked main PBX or
dedicated connection) for certain number groups, the route to be used for the outgoing call can
be selected for each entry.
Line 4 shows a setting in the case of which all calls for the site "089722=MchH" are routed via
route 3 (main PBX). At the same time, the digits dialled are replaced with another character
string (e.g. number of a dedicated connection in the main PBX).
An internal user can be prevented from selecting a specific network provider by replacing the
prefix of this particular network provider with that of another. This is set centrally. In line 5, the
alternative network provider "0211" is always replaced with "04" (Telecom) and the subsequent
digits forwarded transparently.
Line 6 shows how it can be set that all numbers beginning with the digits "55..." are routed via
route 2 and replaced with the dial string "08972255...". DDI numbers belonging to a different
site can thus be dialled in the same way as internal numbers.
8-10
1.
Replace with
(max. 7 digits)
-
-
-
900
04
08972255
2.
3.
Route
1
4
4
3
2
2
Hicom 100 E Version 2.1, Service manual
A31003-K16-X001-3-7620
,
07/99