10.7.4.2

V.24 port for call charges/extension

The call charges/ext. printout is assigned to V.24 port 1 (MB) by default.
Example: assigning the call charges/ext. printout to V.24 port 3 (2nd SIB module)
Input sequence
A
2 1 3 2 2 (up to SW 2.0.2)
2 1 13 22 (as of SW 2.1)
B
*
C
3
D
<OK>
E
<F8>
The call charges/ext. printout can be assigned to the appropriate port number by entering a
number from 1 to 5 under point C.
10.7.4.3
V.24 port for call charges/line
The call charges/line printout is assigned to V.24 port 1 (MB) by default.
Example: assigning the call charges/line printout to V.24 port 4 (3rd SIB module)
Input sequence
A
2 1 3 2 3 (up to SW 2.0.2)
2 1 13 23 (as of SW 2.1)
B
*
C
4
D
<OK>
E
<F8>
The call charges/line printout can be assigned to the appropriate port number by entering a
number from 1 to 5 under point C.
A31003-K16-X001-3-7620, 07/99
Hicom 100 E Version 2.1, Service manual
Meaning
V.24 port for call charges/ext.
Change input
Select port 3
Confirm input
Return to Start menu
Meaning
V.24 port for call charges/line
Change input
Selecting port 4
Confirm input
Return to Start menu
Programming guide
System settings
Display
Port: 1
Port:
Port: 3
Port: 3
System administration
Display
Port: 1
Port:
Port: 4
Port: 4
System administration
10-59