Connection Via Tfe/V Adapter Box; Figure 11-12 Connection To Siedle Tlm 511-01, Ritto 5760 Or Grothe Ts 6216 - Siemens Hicom 100 E Service Manual

Table of Contents

Advertisement

11.3.4

Connection via TFE/V adapter box

Depending on the features required, the door opener can be connected via an entrance tele-
phone adapter box with amplifier (TFE/V) (S30817-Q936-A313, with make contact).
In the case of the a/b interface, the a-wire is always to be connected to minus and the b-
wire to plus.
Grothe
TS 6216
L
O
B
U
LS1/LS2 = Loudspeaker
MIC +/MIC- = Microphone
a/b = Subscriber line circuit
KLI/KLI = Doorbell contact
AC/AC = Doorbell transformer
TOE/TOE = Door opener relay
- The potentiometer for setting the volume should, if possible, be set to the max. volume (turn as far right as
possible).
- Do not change jumper X1 (GER)
- Door opener contact load: 2A max.
Figure 11-12Connection to Siedle TLM 511-01, Ritto 5760 or Grothe TS 6216 entrance
telephone
A31003-K16-X001-3-7620, 07/99
Hicom 100 E Version 2.1, Service manual
Siedle
RiTTO
TLM 511-01
5760
2
12
+
13
+
14
6
11
Doorbell
Door opener
relay
Hicom 100E
LSI
LSI
MIC+
MIC-
X5 terminal
X2 jumper
A
B
KLI
KLI
AC
AC
TOEI
TOEI
a
b
8 x 12 V doorbell
transformer
Plus products
Entrance telephones
TFE/V
X1 jumper
Potentiometer
X4 terminal
X3 terminal
Power supply
11-13