10.7.3

Setting the V.24 interface baud rate (as of SW 2.0.1+)

The V.24 interface baud rate on the MB is set to 2400 by default. The maximum setting is 9600.
Example: changing the baud rate to 9600.
Input sequence
A
2 1 3
(SW 2.0.2)
2 1 3 1 (as of SW2.1)
B
*
C
2
D
<OK>
E
<F8>
The baud rate can be set to 2400 by entering "1" under point C.
10.7.4
V.24 port allocation for data output (as of SW version 2.0.2)
By installing SIB modules, up to 4 extra V.24 interfaces with a permanent baud rate of 2400 are
available in addition to the V.24 interface on the MB as of SW version 2.0.2. All 5 possible ports
allow customer data to be uploaded and downloaded with the help of the PC tool "Assistant L".
The printout of different types of call charge data and the customer data can be assigned to
individual ports.
10.7.4.1
V.24 port for CDRC (Call Detail Recorder)
The CDRC (call detail recording, central) printout is not released by default and may only be
assigned to a port if a call charge printer or computer is connected to this port.
Example: assigning the CDRC printout to V.24 port 2 (1st SIB module)
Input sequence
A
2 1 3 2 1(up to SW2.0.2)
2 1 1 3 21 (as of SW2.1)
B
*
C
2
D
<OK>
E
<F8>
The CDRC printout can be deactivated by pressing the F3 key under point C. Entries 1 to 5 refer
to the port number.
10-58
Meaning
Baud rate V.24
Change input
Select 9600 baud
Confirm input
Return to Start menu
Meaning
V.24 port for CDRC
Change input
Select port 2
Confirm input
Return to Start menu
Display
Value: 2400 baud
Value:
Value: 9600 baud
Value: 9600 baud
System administration
Port: –
Port:
Port: 2
Port: 2
System administration
A31003-K16-X001-3-7620
Hicom 100 E Version 2.1, Service manual
Display
,
07/99

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hicom 118Hicom 108Hicom 118-2Hicom 112

Table of Contents