The range is 1 to 255. The default value is 30.
9.
In the Init TTL field, enter the initial TTL to be used.
The range is 1 to 255. The default value is 1.
10.
In the MaxFail field, enter the maximum number of failures allowed in the session.
The range is 0 to 255. The default value is 5.
11.
In the Interval (secs) field, enter the time between probes in seconds.
The range is 1 to 60. The default value is 3.
12.
In the Port field, enter the UDP destination port for the probe packets.
The range is 1 to 65535. The default value is 33434.
13.
In the Size field, enter the size of the probe packets.
The range is 64 to 1472. The default value is 64.
14.
Click the Apply button.
A traceroute request is sent to the specified IPv4 address or host name. The results are
displayed below the configurable data in the Results field.
If a reply to the traceroute is received, a message similar to the following one is displayed:
1 10.5.225.33 20 ms 10 ms 30 ms
2 10.5.225.225 10 ms 10 ms 10 ms
3 192.254.254.3 10 ms 30 ms 20 ms
Hop Count = 3 Test attempt = 9 Test Success = 3

Send an IPv6 Traceroute

Use this page to tell the switch to send a traceroute request to a specified IPv6 address or
host name. You can use this to discover the paths that packets take to a remote destination.
Once you click the Apply button, the switch sends a traceroute and the results are displayed
below the configurable data.
To send an IPv6 traceroute:
1.
Connect your computer to the same network as the switch.
You can use a WiFi or wired connection to connect your computer to the network, or
connect directly to a switch that is off-network using an Ethernet cable.
2.
Launch a web browser.
3.
In the address field of your web browser, enter the IP address of the switch.
If you do not know the IP address of the switch, see
Switch
on page 10.
The login window opens.
4.
Enter the switch's password in the Password field.