XCP Issues Fixed in Releases Earlier Than XCP 1121 (Continued)
TABLE 3-3
M4000
ID
M3000
M5000
RTIF1-
O
111005-001
RTIF1-
O
O
111028-001
M8000
M9000 Description
O
M4000/M5000 servers:
When the system board is mounted
with the onboard I/O device, if you
use the addboard(8) or
moveboard(8) command to add or
move it by DR, operation may fail.
M8000/M9000 servers:
When the system board is mounted
with one or more PCI cards, if you use
the addboard(8) or moveboard(8)
command to add or move it by DR,
operation may fail.
However, when it is mounted with
the IOUA card only, this event does
not occur.
In either case, the following message
appears on the destination domain
console of the system board addition
or move:
interpreter[xxxx]: ABORT: Bus
Error: Fault Addr: 0xXXXXXXXX
efdaemon[xxx]: Wait pid: xxxx
status: xxx
WARNING: IKP: Unable to
probe PCI leaf (x-x-x)
O
In the setemailreport(8),
setsmtp(8) or setupplatform(8)
command, any of the following
characters in the e-mail address will
result in an error.
!#$%&'*+/=?^`{|}~
Workaround
M4000/M5000 servers:
No workaround is available.
M8000/M9000 servers:
No workaround is available.
Do not specify these characters in the
e-mail address.
Chapter 3
Information About Software
49