Fujitsu SPARC Enterprise M3000 Product Notes page 56

Hide thumbs Also See for SPARC Enterprise M3000:
Table of Contents

Advertisement

XCP Issues Fixed in Releases Earlier Than XCP 1121 (Continued)
TABLE 3-3
M4000
ID
M3000
M5000
RTIF1-
O
080620-001
RTIF1-
O
080725-003
RTIF1-
O
O
080725-004
RTIF1-
O
080808-001
RTIF1-
O
O
081006-001
RTIF1-
O
O
081006-002
RTIF1-
O
081006-003
40
SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1121 • February 2016
M8000
M9000 Description
O
The SNMP trap not notified in the
event that the power cable of the
server got unplugged accidentally.
O
The initial value that set with the
setdomparam set-defaults option
differs from the initial value of
OpenBoot PROM.
parameters
current value
expected value
diag-level none(0x00)
min(0x20)
auto-boot? false(0x00)
true(0xff)
O
After set the Daylight Saving Time by
using the XSCF shell, XSCF Web does
not show the correct time in the Logs
menu.
O
On the cluster system using the
PRIMECLUSTER software, when
there are 10 or more RCI units, the
RCI busy status may be temporarily
unreleased and output the following
syslog message:
SA_pprcir.so to test host
host_name failed
O
The error log "XSCF FMEM write
error" recorded and the firmware
update might fail.
O
In the setemailreport(8)
command, when you specified over
255 characters in the SMTP address,
an error results.
During the domain operation, after
the XSCF reset due to the XSCF unit
failure, the hardware status shows
Deconfigure in the status of CPU
and memory.
Workaround
No workaround is available.
In the OpenBoot PROM prompt (ok),
execute the set-defaults command
to restore the OpenBoot PROM
environmental variables to the initial
value.
No workaround is available.
Use the showlogs(8) command of the
XSCF shell.
Refer to the manual of the
PRIMECLUSTER software to check
the cluster status. If no problem found
on the status, this message can be
safely ignored. If any problem, follow
the instructions on the manual to
solve the problem.
Power off (AC OFF) the system, and
power on (AC ON) again. Then, re-
execute the firmware update.
Do not specify over 255 characters in
the SMTP address.
Replace the motherboard unit only.
When no failure found on the
memory, you do not need to replace
the memory.

Advertisement