Table 9
Job aid: Setup utility prompt descriptions (cont'd.)
Prompt
Please provide primary
image-file path
[/flash/p80a4100.img]:
Please add system prompt
[ERS-8606]:
Please select CPU primary slot
(5/6) [5]:
Primary CPU mgmt port:
autonegotiation [n] (y/n)?
speed (10/100) [10]:
Do you want to enable
automatic savetostandby
mode [n] (y/n)?
Copyright © 2008 Nortel Networks
.
Configuring the switch with the setup utility 55
Description and action
Description: Indicates the name of the
primary image file.
Action: Press Enter to accept the default
(p80a4100.img), or type a different file name
for the primary image file. To specify the path
to the file is optional. If your run-time image
resides on your PCMCIA card, you must
specify the path as /PCMCIA/ filename.
Description: Specifies the text for the
prompt.
Action: Press Enter to accept the default
(ERS-8610), or type a different string of up to
20 characters.
Description: Indicates the slot number of the
primary central processing unit (CPU). The
slot can be 5 or 6.
Action: Press Enter to accept the default (5),
or specify 6.
Description: Specifies if you want the
primary CPU to use autonegotiation.
Action: Enter n to accept the default, or enter
y to indicate that you want the primary CPU
management port to use autonegotiation.
Description: Specifies the line speed in Mb/s.
Action: Press Enter to accept the default (10
Mb/s), or specify 100 Mb/s.
Description: Specifies if you want the boot
and run-time configuration files to be saved on
the backup CPU.
Action: Enter y to save the boot and run-time
configuration files on the backup CPU. Accept
the default (n) to save boot and run-time
configuration files on the primary CPU.
Nortel Ethernet Routing Switch 8600
Commissioning
NN46205-319 01.01 Standard
30 May 2008