Nortel Passport 8600 Installation Manual
Nortel Passport 8600 Installation Manual

Nortel Passport 8600 Installation Manual

Sfp, xfp, and gbic hardware components
Hide thumbs Also See for Passport 8600:
Table of Contents

Advertisement

Nortel Metro Ethernet Routing Switch 8600
Installation — SFP, XFP, and
GBIC Hardware Components
NN46220-301 (324012-A Rev 02)
.

Advertisement

Table of Contents
loading

Summary of Contents for Nortel Passport 8600

  • Page 1 Nortel Metro Ethernet Routing Switch 8600 Installation — SFP, XFP, and GBIC Hardware Components NN46220-301 (324012-A Rev 02)
  • Page 2 While the information in this document is believed to be accurate and reliable, except as otherwise expressly agreed to in writing NORTEL PROVIDES THIS DOCUMENT "AS IS" WITHOUT WARRANTY OR CONDITION OF ANY KIND, EITHER EXPRESS OR IMPLIED. The information and/or products described in this document are subject...
  • Page 3: Table Of Contents

    Procedure job aid: locking and extractor mechanisms 24 Removing an SFP 25 Gigabit interface converters Selecting a GBIC 27 Installation — SFP, XFP, and GBIC Hardware Components Copyright © 2007, Nortel Networks Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
  • Page 4 10GBASE-SR XFP specifications 60 10GBASE-LR/LW XFP specifications 62 10GBASE-ER/EW XFP specifications 63 10GBASE-ZR/ZW XFP specifications 64 Installation — SFP, XFP, and GBIC Hardware Components Copyright © 2007, Nortel Networks Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
  • Page 5: New In This Release

    New in this release The following sections detail what’s new in Nortel Installation — SFP, XFP, and GBIC Hardware Components for Metro Ethernet Routing Switch Release 4.2 and Ethernet Services Unit 1800 and 1850 Release 3.4: • "Features" (page 5) •...
  • Page 6: 1000Base-Bx Sfp Specification Updates

    The specifications for the 1000BASE-BX SFP are updated (see "1000BASE-BX DDI SFP specifications" (page Document changes This document is reformatted to comply with Nortel Customer Documentation Standards (NCDS) guidelines. Installation — SFP, XFP, and GBIC Hardware Components Copyright © 2007, Nortel Networks Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard...
  • Page 7: Introduction

    Installation — SFP, XFP, and GBIC Hardware Components Copyright © 2007, Nortel Networks clock data recovery coarse wavelength-division multiplexing differential mode delay electromagnetic interference electrostatic discharge Gigabit Interface Converters Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
  • Page 8 Twisted Pair Ethernet unshielded twisted pair wide area network wavelength-division multiplexing 10 Gigabit Ethernet small form factor pluggable Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
  • Page 9: Safety And Regulatory Information

    The wrist strap should touch the skin and be grounded through a one megaohm resistor. Installation — SFP, XFP, and GBIC Hardware Components Copyright © 2007, Nortel Networks "Electrostatic discharge prevention" Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
  • Page 10: Care Of Fiber Optic Equipment

    flat on a shelf. Frequent overstressing of fiber optic cable causes progressive degeneration that leads to failure. Installation — SFP, XFP, and GBIC Hardware Components Copyright © 2007, Nortel Networks Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
  • Page 11: Fiber Optic Connector Care

    To avoid the transfer of oil or other contaminants from your fingers to the end face of the ferrule, handle connectors with care. Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
  • Page 12: Job Aid: Connector Cleaning Tools And Materials

    Do not allow the air extension tube to touch the bottom of the optical port. —End— Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
  • Page 13: Cleaning Duplex Sc Connectors

    Do not discard the shroud. On retractable shroud connectors, hold the shroud in its retracted position. —End— Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007 Care of fiber optic equipment 13...
  • Page 14: Product Safety Warnings And Information

    Fiber optic equipment can emit laser or infrared light that can injure your eyes. Never look into an optical fiber or connector port. Always assume that fiber optic cables are connected to a light source. ATTENTION ATTENTION Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
  • Page 15: Electromagnetic Interference Compliance

    WARNING Use of controls or adjustments, or performance of procedures other than those specified herein can result in hazardous radiation exposure. Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
  • Page 16 European EN 55 022 statement This is to certify that the Nortel Networks optical routing system is shielded against the generation of radio interference in accordance with the application of Council Directive 89/336/EEC, Article 4a. Conformity is declared by the application of EN 55 022 Class A (CISPR 22).
  • Page 17 B prescrites dans le Règlement sur le brouillage radioélectrique du ministère des Communications du Canada. Installation — SFP, XFP, and GBIC Hardware Components Copyright © 2007, Nortel Networks Electromagnetic interference compliance 17 Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
  • Page 18 18 Safety and regulatory information Nortel Metro Ethernet Routing Switch 8600 Installation — SFP, XFP, and GBIC Hardware Components NN46220-301 02.02 Standard 4.2 13 November 2007 Copyright © 2007, Nortel Networks...
  • Page 19: Small Form Factor Pluggable Transceivers

    Possible media include CAT5, single mode fiber, and multimode fiber. Possible connectors include LC, MT-RJ, and RJ-45. Installation — SFP, XFP, and GBIC Hardware Components Copyright © 2007, Nortel Networks Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
  • Page 20: Procedure Job Aid: Sfps And Common Applications

    Procedure job aid: SFP models without DDI support SFPs are hot-swappable input/output enhancement components designed for use with Nortel products to allow Gigabit Ethernet ports to link with other Gigabit Ethernet ports over various media types. The SFPs described in this section do not have Digital Diagnostic Interface capability, and are RoHS -E5 compliant.
  • Page 21: Procedure Job Aid: Sfp Models With Ddi Support

    AA1419015-E5 AA1419025-E5 to AA1419032-E5 AA1419033-E5 to AA1419040-E5 "SFP specifications" (page Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007 Selecting an SFP 21 Description 850 (nm), up to 275 or 550 m 850 nm, up to 275 or 550 m...
  • Page 22 The SFPs described in this section are all RoHS -E6 compliant. For information about configuring DDM, see Nortel Metro Ethernet Routing Switch 8600 Troubleshooting (NN46220-701). The following table lists and describes the Nortel SFP models with DDI capability. All the optical SFPs use LC connectors. SFP models with DDI capability...
  • Page 23: Installing An Sfp

    Installing an SFP Install an SFP to provide an interface between the switch and the network cable. Installing an SFP takes about 3 minutes. Prerequisites • Verify that the SFP is the correct model for your network configuration. Procedure steps...
  • Page 24: Procedure Job Aid: Locking And Extractor Mechanisms

    SFP with bail lock and extraction mechanism Installation — SFP, XFP, and GBIC Hardware Components Copyright © 2007, Nortel Networks —End— "SFP with bail lock and extraction mechanism" (page Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007 24), the...
  • Page 25: Removing An Sfp

    Depending on your SFP model, to release the SFP, press the locking/extractor mechanism. Installation — SFP, XFP, and GBIC Hardware Components Copyright © 2007, Nortel Networks Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007 Removing an SFP 25...
  • Page 26 If you discard the SFP, be sure to dispose of it according to all national laws and regulations. Installation — SFP, XFP, and GBIC Hardware Components Copyright © 2007, Nortel Networks ATTENTION —End— Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
  • Page 27: Gigabit Interface Converters

    (subscriber connector) type and RJ-45. If the media is optical fiber, determine any wavelength restrictions or requirements. Installation — SFP, XFP, and GBIC Hardware Components Copyright © 2007, Nortel Networks Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
  • Page 28: Procedure Job Aid: Gbic Models

    Procedure job aid: GBIC models GBICs are hot-swappable input/output enhancement components designed for use with Nortel products to allow Gigabit Ethernet ports to link with other Gigabit Ethernet ports over various media types. The following table describes supported GBICs. For specifications for these GBICs, see specifications"...
  • Page 29: Removing A Gbic

    GBICs are keyed to prevent incorrect insertion. If the GBIC resists pressure, do not force it; turn it over, and reinsert it. —End— Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007 Removing a GBIC 29...
  • Page 30 Store the GBIC in a safe place until needed. If you discard the GBIC, be sure to dispose of it according to all national laws and regulations. When you contact a Nortel service representative for troubleshooting purposes, you must have the following information available: •...
  • Page 31: Gigabit Small Form Factor Pluggable Transceivers

    Factor Pluggable (XFP) transceivers, and lists some technical specifications for the supported XFP models. Nortel recommends that you only use Nortel qualified XFPs. If you do choose to use other vendor XFPs, be aware that Nortel does not support the use of other XFPs. Navigation •...
  • Page 32: Procedure Job Aid: Xfp Models

    Procedure job aid: XFP models XFPs are hot-swappable input/output enhancement components designed for use with Nortel products to allow 10 Gigabit Ethernet ports to link with other 10 Gigabit Ethernet ports. Digital diagnostic monitoring (DDM) allows real-time access to device operating parameters. All XFPs come with DDM capability.
  • Page 33: Installing An Xfp

    Model number 10GBASE-ER/EW 10GBASE-ZR/ZW Installing an XFP Install an XFP to provide a 10 Gigabit Ethernet interface between the switch and other network devices. Installing an XFP takes about 3 minutes. Prerequisites • Verify that the XFP is the correct model for your network configuration.
  • Page 34: Removing An Xfp

    Procedure steps Step Action Disconnect the network fiber cable from the XFP connector. Installation — SFP, XFP, and GBIC Hardware Components Copyright © 2007, Nortel Networks —End— Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
  • Page 35 If you discard the XFP, be sure to dispose of it according to all national laws and regulations. Installation — SFP, XFP, and GBIC Hardware Components Copyright © 2007, Nortel Networks ATTENTION —End— Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007 Removing an XFP 35...
  • Page 36 36 10 Gigabit small form factor pluggable transceivers Nortel Metro Ethernet Routing Switch 8600 Installation — SFP, XFP, and GBIC Hardware Components NN46220-301 02.02 Standard 4.2 13 November 2007 Copyright © 2007, Nortel Networks...
  • Page 37: Sfp Specifications

    "1000BASE-ZX DDI CWDM SFP specifications" (page 46) • "1000BASE-BX DDI SFP specifications" (page 47) Installation — SFP, XFP, and GBIC Hardware Components Copyright © 2007, Nortel Networks Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
  • Page 38: Sfp Labels

    38 SFP specifications • "1000BASE-EX DDI SFP specifications" (page 48) SFP labels The Nortel label on a typical SFP contains a Nortel serial number, a bar code, a manufacturer’s code, an interface type, and a part number. SFP label General SFP specifications The following table describes general SFP specifications.
  • Page 39: 1000Base-T Sfp Specifications

    275 m using 62.5 µm MMF optic cable • up to 550 m using 50 µm MMF optic cable 850 nanometers (nm) 7.0 deciBels (dB) Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
  • Page 40: 1000Base-Sx (Mt-Rj) Sfp Specifications

    275 m using 62.5 µm MMF optic cable • up to 550 m using 50 µm MMF optic cable 850 nm 7.0 dB -10 to -4.0 dBm -17 dBm 0 dBm Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
  • Page 41: 1000Base-Xd Cwdm Sfp Specifications

    -20 dBm -3.0 dBm Specifications Duplex LC SMF, 9 µm 1.0 Gbit/s 1.25 Gbit/s 0 to 60C 17 dB -4.0 to 1.0 dBm -21 dBm -3.0 dBm Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
  • Page 42: 1000Base-Zx Cwdm Sfp Specifications

    Duplex LC SMF, 9 µm 1.0 Gbit/s 1.25 Gbit/s 0 to 60C 20 dB -3.0 to 2.0 dBm -23 dBm -3.0 dBm Specifications 1 watt (W) Duplex LC Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
  • Page 43: 1000Base-Lx Ddi Sfp Specifications

    0 dBm Specifications 1.0 watt (W) Duplex LC SMF, 9 µm 1.0 Gbit/s 1.25 Gbit/s 9.5 dB -9.5 to -3.0 dBm -19.0 dBm -3.0 dBm Specifications 1.0 W Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
  • Page 44: 1000Base-Xd Ddi 1550 Nm Sfp Specifications

    Specification 1.0 W Duplex LC SMF, 9 µm 1.0 Gbit/s 1.25 Gbit/s 22 dB 2 dB at 40 km -2.0 to 3.0 dBm -24 dBm 0 dBm Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
  • Page 45: 1000Base-Zx Ddi Sfp Specifications

    CAUTION To prevent damage to the optical receiver, ensure that at least 4 dB of attenuation is present between the transmit and receive ports. Specifications 1.0 W Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
  • Page 46: 1000Base-Zx Ddi Cwdm Sfp Specifications

    Specifications 1.0 W Duplex LC SMF, 9 µm 1.0 Gbit/s 1.25 Gbit/s 24 dB 2 dB at 70 km 0 to 5.0 dBm -24 dBm -3.0 dBm Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
  • Page 47: 1000Base-Bx Ddi Sfp Specifications

    Copyright © 2007, Nortel Networks 1000BASE-BX DDI SFP specifications 47 Specifications Single-fiber LC 1.0 Gbit/s 1.25 Gbit/s Up to 10 km 1310 nm and 1490 nm 11.0 dB 3.3 dB Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
  • Page 48: 1000Base-Ex Ddi Sfp Specifications

    Specifications 1.2 W Duplex LC SMF, 9 µm 1.0 Gbit/s 1.25 Gbit/s 30 dB 2.0 dB at 120 km 0 to 5.0 dBm -30 dBm -9.0 dBm Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
  • Page 49: Gbic Specifications

    • "1000BASE-EX CWDM GBIC specifications" (page 55) GBIC labels As shown in the following figure, the Nortel label on a typical GBIC contains a Nortel serial number, a bar code, a manufacturer’s code, an interface type, and a part number.
  • Page 50: Gbic Physical Specifications

    Copyright © 2007, Nortel Networks Specifications 0.39 x 1.2 x 2.6 inches (in.) 1.0 x 3.0 x 6.5 centimeters (cm) • Multimode: SC • Single mode: SC • CAT5 RJ-45 Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
  • Page 51: 1000Base-Sx Gbic Specifications

    You must disable autonegotiation before operating the 1000BASE-T GBIC. By default, GBICs inserted into certain product-specific modules are set for Autonegotiation = True. If autonegotiation does not work initially, Nortel recommends that you reconfigure the switch to use a fixed-speed setting of 1000 Mbit/s, full-duplex, on both sides.
  • Page 52: 1000Base-Lx Gbic Specifications

    • up to 550 m using 50 µm MMF 850 nanometers (nm) 7.0 dB -10 to -4.0 deciBels referenced to 1 milliwatt (dBm) -17 dBm 0 dBm Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
  • Page 53 (DMD). Excessive DMD can cause an increase in the bit error rate (BER). You can order mode conditioning patch cords through Nortel: • SC-SC Mode-Conditioning Patch Cord 62.5/125 (part number AA0018035) •...
  • Page 54: 1000Base-Xd Gbic Specifications

    Specifications Duplex SC single mode Up to 50 km 17 dB 1550 ± 10 nm -5.0 to 0 dBm 1200 to 1620 nm -22 dBm -3.0 dBm Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
  • Page 55: 1000Base-Ex Cwdm Gbic Specifications

    SC duplex Up to 70 km 22 dB 1550 ± 10 nm 0.2 nm 0 to 5.0 dBm 1200 nm to 1620 nm -22 dBm -3.0 dBm Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
  • Page 56 λ (x-4) λ (x-4) SMSR 30 dB +2.0 dBm 9 dB 14 dB λ 1450 nm Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007 - typical Typical Maximum (x+1) (x+7) (x+1) (x+6) 0.08 nm/C +6.0 dBm...
  • Page 57 1000BASE-EX CWDM GBIC specifications 57 Symbol Minimum -30 dBm -28 dBm Minimum Typical 250 mA 4.75 V 5.00 V Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007 Typical Maximum -7 dBm -7 dBm 2.0 dB 3.0 dB Maximum...
  • Page 58 58 GBIC specifications Nortel Metro Ethernet Routing Switch 8600 Installation — SFP, XFP, and GBIC Hardware Components NN46220-301 02.02 Standard 4.2 13 November 2007 Copyright © 2007, Nortel Networks...
  • Page 59: Xfp Specifications

    For more details, see these standards documents. All Nortel XFPs meet or exceed these standards. Nortel recommends that you only use Nortel-qualified XFPs. If you do choose to use other vendor XFPs, be aware that Nortel does not support the use of other XFPs. Navigation •...
  • Page 60: General Xfp Specifications

    Copyright © 2007, Nortel Networks Specifications 0.49 x 0.72 x 2.79 inches (in.) 12.5 x 18.35 x 71.1 millimeters (mm) LC ultra physical contact (UPC) -40 to 85C 0 to 70C Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
  • Page 61 3.0 dB -128 dB per Hertz (dB/Hz) -12 dB -9.9 to -1.0 dBm 0 dBm -11.1 dBm -12 dB -7.5 dBm 12.3 gigaHertz (GHz) Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007 10GBASE-SR XFP specifications 61...
  • Page 62: 10Gbase-Lr/Lw Xfp Specifications

    62 XFP specifications The stressed sensitivity values are for system level BER measurements, which include the effects of CDR circuits. Nortel recommends that you allocate at least 0.4 dB additional margin if you make component level measurements without the effect of CDR circuits.
  • Page 63: 10Gbase-Er/Ew Xfp Specifications

    -12 dB -10.3 dBm 12.3 GHz ATTENTION Specifications 10GBASE-ER 10.3125 Gbit/s ±100 ppm 10GBASE-EW 9.95328 Gbit/s ±20 ppm 675 000 hours 1530 to 1565 nm; nominal 1550 nm Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
  • Page 64: 10Gbase-Zr/Zw Xfp Specifications

    -2.1 dBm -1.7 dBm -30 dBm 3.0 dB -128 dB/Hz -21 dB -15.8 dBm to -1.0 dBm 4.0 dBm -14.1 dBm -26 dB -11.3 dBm 12.3 GHz Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
  • Page 65 -26 dB -12 dB 1280 to 1575 nm. Sensitivity specified for 1530 to 1565 nm. 10GBASE-ZR 10.3125 Gbit/s ± 100 ppm 10GBASE-ZW 9.95328 Gbit/s ± 100 ppm Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
  • Page 66 Receive electrical 3 dB upper cutoff frequency Installation — SFP, XFP, and GBIC Hardware Components Copyright © 2007, Nortel Networks Specifications -24 dBm and 9 -7.0 dBm 5.0 dBm -27 dB 9.3 GHz Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
  • Page 67 AA1419071-E6 22, 48 acronyms 7 cleaning, handling fiber optic connectors duplex SC connectors 13 receptacle or duplex devices 13 SC, FC connectors 12 tools and materials 12 Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
  • Page 68 13 safety 9 SC connectors, cleaning 12 1000BASE-BX 47 1000BASE-LX 40 1000BASE-SX 39, 40 1000BASE-T 39 SFP physical specifications 38 troubleshooting 30 XFP specifications 60 Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
  • Page 70 While the information in this document is believed to be accurate and reliable, except as otherwise expressly agreed to in writing NORTEL PROVIDES THIS DOCUMENT "AS IS" WITHOUT WARRANTY OR CONDITION OF ANY KIND, EITHER EXPRESS OR IMPLIED. The information and/or products described in this document are subject to change without notice.