Page 1
Nortel Metro Ethernet Routing Switch 8600 Installation — SFP, XFP, and GBIC Hardware Components NN46220-301 (324012-A Rev 02)
Page 2
While the information in this document is believed to be accurate and reliable, except as otherwise expressly agreed to in writing NORTEL PROVIDES THIS DOCUMENT "AS IS" WITHOUT WARRANTY OR CONDITION OF ANY KIND, EITHER EXPRESS OR IMPLIED. The information and/or products described in this document are subject...
New in this release The following sections detail what’s new in Nortel Installation — SFP, XFP, and GBIC Hardware Components for Metro Ethernet Routing Switch Release 4.2 and Ethernet Services Unit 1800 and 1850 Release 3.4: • "Features" (page 5) •...
To avoid the transfer of oil or other contaminants from your fingers to the end face of the ferrule, handle connectors with care. Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
Do not allow the air extension tube to touch the bottom of the optical port. —End— Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
Do not discard the shroud. On retractable shroud connectors, hold the shroud in its retracted position. —End— Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007 Care of fiber optic equipment 13...
Fiber optic equipment can emit laser or infrared light that can injure your eyes. Never look into an optical fiber or connector port. Always assume that fiber optic cables are connected to a light source. ATTENTION ATTENTION Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
WARNING Use of controls or adjustments, or performance of procedures other than those specified herein can result in hazardous radiation exposure. Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
Page 16
European EN 55 022 statement This is to certify that the Nortel Networks optical routing system is shielded against the generation of radio interference in accordance with the application of Council Directive 89/336/EEC, Article 4a. Conformity is declared by the application of EN 55 022 Class A (CISPR 22).
Procedure job aid: SFP models without DDI support SFPs are hot-swappable input/output enhancement components designed for use with Nortel products to allow Gigabit Ethernet ports to link with other Gigabit Ethernet ports over various media types. The SFPs described in this section do not have Digital Diagnostic Interface capability, and are RoHS -E5 compliant.
AA1419015-E5 AA1419025-E5 to AA1419032-E5 AA1419033-E5 to AA1419040-E5 "SFP specifications" (page Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007 Selecting an SFP 21 Description 850 (nm), up to 275 or 550 m 850 nm, up to 275 or 550 m...
Page 22
The SFPs described in this section are all RoHS -E6 compliant. For information about configuring DDM, see Nortel Metro Ethernet Routing Switch 8600 Troubleshooting (NN46220-701). The following table lists and describes the Nortel SFP models with DDI capability. All the optical SFPs use LC connectors. SFP models with DDI capability...
Installing an SFP Install an SFP to provide an interface between the switch and the network cable. Installing an SFP takes about 3 minutes. Prerequisites • Verify that the SFP is the correct model for your network configuration. Procedure steps...
Procedure job aid: GBIC models GBICs are hot-swappable input/output enhancement components designed for use with Nortel products to allow Gigabit Ethernet ports to link with other Gigabit Ethernet ports over various media types. The following table describes supported GBICs. For specifications for these GBICs, see specifications"...
GBICs are keyed to prevent incorrect insertion. If the GBIC resists pressure, do not force it; turn it over, and reinsert it. —End— Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007 Removing a GBIC 29...
Page 30
Store the GBIC in a safe place until needed. If you discard the GBIC, be sure to dispose of it according to all national laws and regulations. When you contact a Nortel service representative for troubleshooting purposes, you must have the following information available: •...
Factor Pluggable (XFP) transceivers, and lists some technical specifications for the supported XFP models. Nortel recommends that you only use Nortel qualified XFPs. If you do choose to use other vendor XFPs, be aware that Nortel does not support the use of other XFPs. Navigation •...
Procedure job aid: XFP models XFPs are hot-swappable input/output enhancement components designed for use with Nortel products to allow 10 Gigabit Ethernet ports to link with other 10 Gigabit Ethernet ports. Digital diagnostic monitoring (DDM) allows real-time access to device operating parameters. All XFPs come with DDM capability.
Model number 10GBASE-ER/EW 10GBASE-ZR/ZW Installing an XFP Install an XFP to provide a 10 Gigabit Ethernet interface between the switch and other network devices. Installing an XFP takes about 3 minutes. Prerequisites • Verify that the XFP is the correct model for your network configuration.
38 SFP specifications • "1000BASE-EX DDI SFP specifications" (page 48) SFP labels The Nortel label on a typical SFP contains a Nortel serial number, a bar code, a manufacturer’s code, an interface type, and a part number. SFP label General SFP specifications The following table describes general SFP specifications.
275 m using 62.5 µm MMF optic cable • up to 550 m using 50 µm MMF optic cable 850 nanometers (nm) 7.0 deciBels (dB) Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
275 m using 62.5 µm MMF optic cable • up to 550 m using 50 µm MMF optic cable 850 nm 7.0 dB -10 to -4.0 dBm -17 dBm 0 dBm Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
Specification 1.0 W Duplex LC SMF, 9 µm 1.0 Gbit/s 1.25 Gbit/s 22 dB 2 dB at 40 km -2.0 to 3.0 dBm -24 dBm 0 dBm Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
CAUTION To prevent damage to the optical receiver, ensure that at least 4 dB of attenuation is present between the transmit and receive ports. Specifications 1.0 W Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
Specifications 1.0 W Duplex LC SMF, 9 µm 1.0 Gbit/s 1.25 Gbit/s 24 dB 2 dB at 70 km 0 to 5.0 dBm -24 dBm -3.0 dBm Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
Specifications 1.2 W Duplex LC SMF, 9 µm 1.0 Gbit/s 1.25 Gbit/s 30 dB 2.0 dB at 120 km 0 to 5.0 dBm -30 dBm -9.0 dBm Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
• "1000BASE-EX CWDM GBIC specifications" (page 55) GBIC labels As shown in the following figure, the Nortel label on a typical GBIC contains a Nortel serial number, a bar code, a manufacturer’s code, an interface type, and a part number.
You must disable autonegotiation before operating the 1000BASE-T GBIC. By default, GBICs inserted into certain product-specific modules are set for Autonegotiation = True. If autonegotiation does not work initially, Nortel recommends that you reconfigure the switch to use a fixed-speed setting of 1000 Mbit/s, full-duplex, on both sides.
• up to 550 m using 50 µm MMF 850 nanometers (nm) 7.0 dB -10 to -4.0 deciBels referenced to 1 milliwatt (dBm) -17 dBm 0 dBm Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
Page 53
(DMD). Excessive DMD can cause an increase in the bit error rate (BER). You can order mode conditioning patch cords through Nortel: • SC-SC Mode-Conditioning Patch Cord 62.5/125 (part number AA0018035) •...
Specifications Duplex SC single mode Up to 50 km 17 dB 1550 ± 10 nm -5.0 to 0 dBm 1200 to 1620 nm -22 dBm -3.0 dBm Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
SC duplex Up to 70 km 22 dB 1550 ± 10 nm 0.2 nm 0 to 5.0 dBm 1200 nm to 1620 nm -22 dBm -3.0 dBm Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007...
Page 56
λ (x-4) λ (x-4) SMSR 30 dB +2.0 dBm 9 dB 14 dB λ 1450 nm Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007 - typical Typical Maximum (x+1) (x+7) (x+1) (x+6) 0.08 nm/C +6.0 dBm...
Page 57
1000BASE-EX CWDM GBIC specifications 57 Symbol Minimum -30 dBm -28 dBm Minimum Typical 250 mA 4.75 V 5.00 V Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007 Typical Maximum -7 dBm -7 dBm 2.0 dB 3.0 dB Maximum...
For more details, see these standards documents. All Nortel XFPs meet or exceed these standards. Nortel recommends that you only use Nortel-qualified XFPs. If you do choose to use other vendor XFPs, be aware that Nortel does not support the use of other XFPs. Navigation •...
Page 61
3.0 dB -128 dB per Hertz (dB/Hz) -12 dB -9.9 to -1.0 dBm 0 dBm -11.1 dBm -12 dB -7.5 dBm 12.3 gigaHertz (GHz) Nortel Metro Ethernet Routing Switch 8600 NN46220-301 02.02 Standard 4.2 13 November 2007 10GBASE-SR XFP specifications 61...
62 XFP specifications The stressed sensitivity values are for system level BER measurements, which include the effects of CDR circuits. Nortel recommends that you allocate at least 0.4 dB additional margin if you make component level measurements without the effect of CDR circuits.
Page 70
While the information in this document is believed to be accurate and reliable, except as otherwise expressly agreed to in writing NORTEL PROVIDES THIS DOCUMENT "AS IS" WITHOUT WARRANTY OR CONDITION OF ANY KIND, EITHER EXPRESS OR IMPLIED. The information and/or products described in this document are subject to change without notice.