Universal Dialing Plan - Nortel Remote Gateway 50 Configuration Manual

Main office configuration for survivable remote gateway
Hide thumbs Also See for Remote Gateway 50:
Table of Contents

Advertisement

Page 216 of 258

Universal Dialing Plan

553-3001-207
Standard 2.00
Dialing Plan configuration
For more information on configuring the main office and NRS, refer to
Branch Office: Installation and Configuration (553-3001-214) and IP Peer
Networking: Installation and Configuration (553-3001-213). For more
information on configuring the SRG, refer to SRG50 Configuration Guide.
Overview
Figure 74 on
page 217
using location codes (Access Code + LOC + DN) configuration.
In this type of dialing plan, the DNs on the SRG do not need to be different
from the BUID, since the location code (LOC) defines the unique node
characteristic. Therefore, in this example:
The SRG IP Phone has DN 3002 and BUID 3002. (The system adds the
routing code and LOC code to the BUID).
The local telephone has a DN of 3101.
The main office has a telephone configured as TN 3001.
On the main office, the AC1 steering code for the SRG is 6 and the LOC
is 504.
On the SRG, the destination code for the main is 6 and the LOC is 501.
January 2006
shows an example of a Uniform Dialing Plan (UDP)