Page 232 of 258
LD 24 – Configure Emergency Services Access. (Part 2 of 2)
Prompt
Response
DDGT
x...x
DFCL
x...x
OSDN
x...x
553-3001-207
Standard 2.00
Emergency Services configuration
Description
Directing Digits (for CAMA Trunks)(for example, 1, 11, or 911).
Up to four digits are accepted.
Default ESA Calling Number. The input must be the following
lengths:
• On a system that is not FNP equipped, 8 or 11 digits are
accepted if the first digit of the input is '1'; otherwise the input
must be 7 or 10 digits.
• On a system that is FNP equipped, up to 16 digits are
allowed.
On-Site Notification station DN. The input must be a valid single
appearance internal DN.
5
Test ESDN using a main office telephone to confirm that main office calls
exit the main office trunks.
If OSDN is used, the ESA route number must be blank to make test calls
without using any trunk resources. It the route number has been
configured, remove it by entering "x" at the prompt. Nortel recommends
that the system administrator arrange a test call with the Public Services
Access Point (PSAP).
6
Configure the branch office zone on the main office.