Configuration
To configure the main office:
•
Configure the ESN Control Block for CDP in LD 86.
> LD 86
REQ NEW
CUST 0
FEAT ESN
CDP YES
MXSC 50
NCDP 4
DLTN YES
•
Configure the CDP Distant Steering Code (DSC) in LD 87.
> LD 87
REQ NEW
CUST 0
FEAT CDP
TYPE DSC
DSC 4
FLEN 4
RLI 12
To configure the NRS (H.323 Gatekeeper):
•
Create CDP Domain: "MO_BO_CDP".
•
Create H.323 endpoints: "MO", "BO".
•
Create Numbering Plan entries in CDP Domain:
— Add "4" for endpoint "BO".
— Add "30" for endpoint "MO".
To configure the SRG:
•
Set the BUID to the same number that was assigned for the TN by the
main office.
•
Set the main office VoIP Trunk Access code to 0.
•
Do not assign a value to the main office trunk access code field.
Main Office Configuration for Survivable Remote Gateway 50
Dialing Plan configuration
Page 215 of 258
Configuration Guide