Connecting The Drain Piping; To Connect The Piping On Right Side, Right-Back, Or Right-Bottom; To Connect The Piping On Left Side, Left-Back, Or Left- Bottom; To Check For Water Leaks - Daikin CTXM15A5V1B Installation Manual

Hide thumbs Also See for CTXM15A5V1B:
Table of Contents

Advertisement

6 Piping installation

NOTICE
Do NOT use nippers to remove the pipe port cover, as this
would damage the front grille.
5.3

Connecting the drain piping

5.3.1
To connect the piping on right side, right-
back, or right-bottom
INFORMATION
The factory default is right-side piping. For left-side piping,
remove the piping from the right side and install it on the
left side.
1 Attach the drain hose with adhesive vinyl tape to the bottom of
the refrigerant pipes.
2 Wrap the drain hose and the refrigerant pipes together using
insulation tape.
A
C
a b
B
A
Right-side piping
B
Right-bottom piping
C
Right-back piping
a
Remove the pipe port cover here for right side piping
b
Remove the pipe port cover here for right-bottom piping
5.3.2
To connect the piping on left side, left-
back, or left-bottom
INFORMATION
The factory default is right-side piping. For left-side piping,
remove the piping from the right side and install it on the
left side.
1 Remove the insulation fixing screw on the right side and
remove the drain hose.
2 Remove the drain plug on the left side and attach it to the right
side.
NOTICE
Do NOT apply lubricating oil (refrigerant oil) to the drain
plug when inserting it. The drain plug may deteriorate and
cause drain leakage from the plug.
3 Insert the drain hose on the left side and do not forget to tighten
it with the fixing screw; otherwise water leakage may occur.
a
b
a
Insulation fixing screw
b
Drain hose
4 Attach the drain hose to the refrigerant piping bottom side using
adhesive vinyl tape.
Installation manual
6
5.3.3
1 Remove the air filters.
2 Gradually pour approximately 1 l of water in the drain pan, and
6
6.1
6.1.1
▪ Foreign materials inside pipes (including oils for fabrication) must
Refrigerant piping diameter
Use the same diameters as the connections on the outdoor units:
Refrigerant piping material
a
▪ Piping material: phosphoric acid deoxidised seamless copper
▪ Flare connections: Only use annealed material.
b
▪ Piping temper grade and thickness:
b
A
Left-side piping
B
Left-back piping
C
Left-bottom piping
a
Remove the pipe port cover here for left-side piping
b
Remove the pipe port cover here for left-bottom piping

To check for water leaks

check for water leaks.
Piping installation

Preparing refrigerant piping

Refrigerant piping requirements

CAUTION
Piping and joints of a split system shall be made with
permanent joints when inside an occupied space except
joints directly connecting the piping to the indoor units.
NOTICE
The piping and other pressure-containing parts shall be
suitable for refrigerant. Use phosphoric acid deoxidised
seamless copper for refrigerant piping.
be ≤30 mg/10 m.
Class
Pipe outer diameter (mm)
Liquid pipe
15~42
Ø6.4
50
Ø6.4
a
A
B
C
Gas pipe
Ø9.5
Ø12.7
CTXM-A, FTXM-A, ATXM-A
Daikin room air conditioner
3P697375-8B – 2023.06

Advertisement

Table of Contents
loading

Table of Contents