SiBE05-311
2.2

Removal of Bell mouth and Left Side Plate

Procedure
Step
1
The bell mouth is
attached to the front
plate with two screws
and four hooks.
2
Remove the two screws
and undo the four
hooks to release the
bell mouth.
Removal Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work
Procedure
.
Hook A
Hook B
Screw
(R1456)
Hook B
(R1457)
Outdoor Unit
Points
Remove the bell mouth from
the front plate after removing
the two screws which are set
below.
Slide the bell mouth in the
arrow direction to disengage
the hook B.