DOME/READING LAMP UNIT
REMOVAL
(1) Disconnect and isolate the battery negative
cable.
(2) Insert the tip of a small flat-bladed screwdriver
into the notch on one edge of the dome/reading lamp
housing to depress the retainer clip and pull that
edge of the lamp away from its mounting location
(Fig. 6).
Fig. 6 Dome/Reading Lamp Unit Remove/Install
1 - LAMP HOUSING
2 - SWITCH BUTTON
3 - NOTCH
4 - SUN VISOR (2)
5 - HEADLINER
(3) Pull the dome/reading lamp unit from its
mounting location far enough to access and discon-
nect the vehicle wire harness from the lamp connec-
tor receptacle.
(4) Remove the dome/reading lamp unit from its
mounting location.

INSTALLATION

(1) Position the dome/reading lamp unit to its
mounting location.
(2) Reconnect the vehicle wire harness connector
to the dome/reading lamp connector receptacle (Fig.
6).
(3) Position the edge of the dome/reading lamp
housing opposite from the retainer clip into the
mounting hole.
(4) Push firmly and evenly on the notched edge of
the dome/reading lamp housing until the retainer
clip latches into place.
(5) Reconnect the battery negative cable.
DOME LAMP/INTRUSION
SENSOR BULB
REMOVAL
(1) Disconnect and isolate the battery negative
cable.
(2) Remove the dome lamp/intrusion sensor unit
from its mounting location, but do not disconnect the
vehicle wire harness from the lamp connector recep-
tacle. (Refer to 8 - ELECTRICAL/LAMPS/LIGHTING
- INTERIOR/DOME LAMP/INTRUSION SENSOR
UNIT - REMOVAL).
(3) Grasp the lamp housing in one hand and rotate
the bulb holder and bulb unit counterclockwise about
30 degrees on the circuit board (Fig. 7).
Fig. 7 Dome Lamp/Intrusion Sensor Bulb Remove/
1 - BULB HOLDER/BULB (4)
2 - LAMP HOUSING
(4) Pull the bulb holder and bulb unit straight out
from the mounting hole in the circuit board.
INSTALLATION
(1) Grasp the dome lamp/intrusion sensor unit
housing in one hand and align the bulb holder and
bulb unit with the bulb mounting hole in the circuit
board with the other hand (Fig. 7).
(2) Insert the bulb holder and bulb unit straight
into the circuit board bulb mounting hole until it is
firmly seated.
(3) Rotate the bulb holder and bulb unit clockwise
about 30 degrees on the circuit board.
(4) Reinstall the dome lamp/intrusion sensor unit
into its mounting location. (Refer to 8 - ELECTRI-
CAL/LAMPS/LIGHTING - INTERIOR/DOME LAMP/
INTRUSION SENSOR UNIT - INSTALLATION).
(5) Reconnect the battery negative cable.