s) Cover support plate (right)
Removing cover support plate (right)
1) When removing the cover support plate(right)[2], open the top cover, left circle cover, tank cover, right circle cover, right upper cover, operation panel, mist
filter, filter cover, filter, right cover, lower rear cover, cover guide, and upper rear cover.
2) Remove the three screws[1], and then remove the cover support plate(right)[2].
t) Cover support plate (left)
Rmoving the cover support plate (left)
1) When removing the cover support plate (left)[2], open the top cover, left circle cover, tank cover, right circle cover, rightupper cover, operation panel, mist filter,
filter cover, filter, right cover, lower rear cover, and upper rear cover.
2) Remove the three screws[1], and then remove the cover support plate (left)[2].

4.3.5 Driving Unit

a) Feed motor
Removing the feed motor
1) When removing the feed motor[1], loosen the two screws[2], and then remove the timing belt[3] from the pulley.
2) Remove the two screws[4] and connector[5], and then remove the feed motor.
[1]
[2]
F-4-27
[2]
[1]
F-4-28
[1]
[3]
[2]
[3]
F-4-29
[1]
[1]
Chapter 4
0012-6368